Receptacles and Extension Cords
Only use high quality, well-insulated, grounded extension cords in good condition with generator receptacles. Extension
cords should have a minimum rating of 125 Volts AC, 20 Amps and should be kept as short as possible to minimize voltage
drop. Follow each load manufacturer’s power rating recommendation when selecting receptacle and extension cord.
This generator is equipped with the following receptacles:
120 Volt AC, 20 Amp receptacle
• Two 120 Volt AC, 20 Amp receptacles.
• 12 Volt 8.3 Amp Output (For charging batteries only)
• This receptacle has a 20 Amp push-to reset circuit breaker to protect against overload.
• Each socket is rated to operate 120 Volt, AC, single phase, 60Hz loads requiring up to 2400 watts (2.4 kW) at 20 Amps.
• Use extension cords having a minimum rating of 125 Volts AC, 20 Amps.
OPERATION
Do not connect 3-phase loads to generator.
CAUTION!
12 Volt 8.3 Amp Output is for charging batteries only!
WARNING!