ENGLISH
•
Turn on the thermal imaging module by briefly pressing the
ON
button
(9)
.
• Turn on the device and align the image centre on the
Krypton XG50
display
with the image centre of the daylight optical device by carefully tilting the
thermal imaging module.
• Align the top and bottom display boundaries of the
Krypton XG50
parallel to
the horizontal line of the daylight optical device’s reticle.
•
Having reached the best possible position of the thermal imaging module,
tighten the two screws
(16)
until stop. The clamping force should be 7 N·m
(use a torque screwdriver to check).
Open
Close
13
14
18
15
19
16
17
Installing Pulsar 5x30 B
Monocular on to the Krypton XG50
The
Pulsar 5x30 B
monocular
(21)
allows you to transform the
Krypton XG50
into a hand-held thermal imager with 5x magnification.
• Align the tabs on the monocular with the slots of the mount
(20)
.
• Turn the monocular clockwise to secure it on the thermal imaging module.
• To remove the monocular, turn it counterclockwise and disconnect from the
thermal imaging module.
Note:
the monocular can be installed on a thermal imaging module with an
adapter already installed.
20
21
5