background image

Table 3. Electrical parameters. 
 
 

Models 

HPSB-12V2A-B 

HPSB-12V3A-B 

HPSB-12V3A-C 

HPSB-12V5A-C 

HPSB-12V7A-C 

HPSB-12V10A-C 

HPSB-12V15A-D 

HPSB-12V20A-E 

PSU type 

A (EPS - External Power Source), II environmental class 

Supply voltage 

~ 200 - 240 V 

Current consumption 

0,4 A 

0,5 A 

0,5 A  

0,8 A 

1 A 

1,3 A 

2 A 

1,5 A 

Power frequency 

50/60 Hz 

Inrush current 

40 A 

50 A 

60 A 

PSU power 

35 W 

48 W 

48 W 

76 W 

97 W 

138 W 

207 W 

276 W 

Output current max. 

2,5 A 

3,5 A 

3,5 A 

5,5 A 

7 A 

10 A 

15 A 

20 A 

Efficiency 

87% 

87% 

87% 

87% 

87% 

87% 

87% 

86% 

Output voltage 

11 - 13,8 V 

– buffer operation 

10 - 13,8 V 

– battery-assisted operation 

Adjustment range U

AUX

 

13,5 

– 14,4 V  

Ripple voltage (max.) 

100 mV p-p 

250 mV p-p 

150 mV p-p 

Current consumption by 
the PSU systems during 
battery-assisted operation 

40 mA 

40 mA 

40 mA 

15 mA 

15 mA 

30 mA 

30 mA 

30 mA 

Fitting battery 

7Ah 

7Ah 

17Ah 

17Ah 

17Ah 

17Ah 

40Ah 

65Ah 

Jumper selectable battery 
charging current 

0,5 A 

 

0,5 A 

0,5 A 

I1: 0,5 A 

I2: 1 A 

I1: 1 A 
I2: 2 A 

I1: 1 A 
I2: 4 A 

I1: 2 A 
I2: 4 A 

I1: 2 A 
I2: 4 A 
I3: 8 A  

Net / gross weight 

1/1,1 kg 

1,3/1,4 kg 

1,7/1,8 kg 

1,8/1,9 kg 

2,3/2,4 kg 

2,6/2,7 kg 

5/5,6 kg 

7/7,8 kg 

Battery circuit protection 
SCP and reverse polarity 
connection 

- polymer fuse 

(returnable)  

- polymer fuse 

(returnable) 

- polymer fuse 

(returnable) 

- F

BAT

 fuse (in case of a failure, fuse-element replacement required) 

Deep discharge battery 
protection UVP 

U<9,5 V (

± 5%) – disconnection of battery terminal 

Optical indication 

- LEDs on PCB of power supply unit  

LED indicators on power supply’s cover (see section 3.1) 

Tamper protection: 
- TAMPER indicates 
enclosure opening 

- microswitch, NC contacts (enclosure closed), 

0,5 A@50 V DC (max.) 

Fuses: - F

BAT

 

T 6,3A/250V 

F 8A/250V 

T 10A/250V 

T15A 

T20A 

Terminals:  
Mains supply: 
Outputs: 
Battery outputs: 
TAMPER: 

 

0,5 

– 2,5 mm

2

 (AWG 26 

– 12) 

 

Battery wires 6,3F 

– 45cm, angle muffs ML062 

Battery wires 

Ф6 (M6-2,5), 45cm 

40cm wires  

Notes 

convectional cooling 

Forced cooling 

Summary of Contents for HPSB Series

Page 1: ...USER MANUAL EN Edition 1 from 24 11 2020 Supersedes the edition Power supplies HPSB series Buffer switched mode power supply...

Page 2: ...l indication 4 Maintenance 1 Technical description 1 1 General description Switch mode buffer power supply units HPSB are intended for continuous power supply to devices that require stabilised voltag...

Page 3: ...utput voltage adjustment 3 Connector to external LED indicators 4 The output of the PSU V V 5 Battery terminals B B 6 L N power supply connector 230V AC protection connector 7 Selection jumper for cha...

Page 4: ...module models 12V10A 24V5A 48V3A Fig 2d View of power supply module models 12V15A 24V7A Fig 2e View of power supply module models 12V20A 24V10A 48V5A Table 2 View of PSU see Fig 3 Element no Descripti...

Page 5: ...www pulsar pl HPSB series 5 Fig 3 View of PSU 1 4 Specifications electrical parameters tab 3 mechanical parameters tab 4 operation safety tab 5 operating parameters tab 6...

Page 6: ...h 17Ah 17Ah 40Ah 65Ah Jumper selectable battery charging current 0 5 A 0 5 A 0 5 A I1 0 5 A I2 1 A I1 1 A I2 2 A I1 1 A I2 4 A I1 2 A I2 4 A I1 2 A I2 4 A I3 8 A Net gross weight 1 1 1 kg 1 3 1 4 kg 1...

Page 7: ...Jumper selectable battery charging current I1 0 2 A I2 0 5 A I1 0 5 A I2 1 A I1 0 5 A I2 2 A I1 1 A I2 2 A I1 1 A I2 2 A I3 4 A I1 0 5 A I2 1 A I1 0 5 A I2 1 A I3 2 A Net gross weight 1 8 1 9 kg 2 3 2...

Page 8: ...sation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport Wg PN 83 T 42106 2 Installation...

Page 9: ...circuit is UNACCEPTABLE It can cause a device failure or an electric shock 3 Check output voltage and adjust if necessary using potentiometer see table displaying parameters of the power supply 4 Con...

Page 10: ...ers WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste According to the European Union WEEE Directive waste electrical and electronic equipment sh...

Reviews: