background image

www.pulsar.pl 

                                                             HPSB7012E

 

 

 

2

 

 

Features: 

 

 

DC 13,8V/6A uninterruptible power supply  

 

fitting battery: 65Ah/12V  

 

wide range of mains supply: 176÷264V  

 

high efficiency 80% 

 

battery charging and maintenance control 

 

excessive discharging (UVP) protection 

 

jumper selectable battery charge current  

     1A/2A 

 

 

battery output full protection against short-
circuit and reverse polarity connection  

 

LED indication  

 

protections: 

 

SCP short-circuit protection 

 

OVP overvoltage protection 

 

overvoltage protection (AC 

input

)  

 

against sabotage 

 

overload protection (OLP) 

  warranty – 2 year from the production date   

 

 

CONTENTS: 
1. Technical description. 

1.1 General description 
1.2 Block diagram 
1.3 Description of PSU components and connectors. 
1.4 Specifications 

2. Installation. 

2.1 Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1 LED indication of operating status 

4. Operation and use. 

4.1 Overload or short circuit of the PSU output (SCP on) 
4.2 Disconnection of discharged battery 

4.3 Maintenance

 

 

 
1. Technical description. 
 

1.1 General description. 

A buffer PSU is intended for an uninterrupted supply to devices requiring stabilised voltage of 

12 V DC (+/-

15%).

 The PSU provides voltage of 

U=13,8 V DC.

 Current efficiency: 

 

1.  Output current 6A + 1A battery charge 
2.  Output current 5A + 2A battery charge  

Total device c battery: 7A max. 
 

In case of power decay, a battery back-up is activated immediately. The PSU is constructed based on the 

switch mode PSU, with high energy efficiency. The PSU is housed in a metal enclosure (colour RAL 9003) which 
can accommodate a 65Ah/12V battery. A micro switch indicates door opening (front cover). 

 

OPTIONAL POWER SUPPLY CONFIGURATIONS:  

(visualisation available at: 

www.pulsar.pl) 

 
1. Buffer power supply unit HPSB 13,8V/4x1,5A/65Ah. 

- HPS  LB4 4x1,5A (AWZ576) + 65Ah 

2. Buffer power supply unit HPSB 13,8V/6x1A/65Ah.

 

- HPS  LB8 6x1A (AWZ579 or  AWZ580) + 65Ah 

3. Buffer power supply unit HPSB 13,8V/12x0,5A/65Ah.

 

- HPS 2xLB8 12x0,5A (AWZ578 or AWZ580) + 65Ah  
- HPS LB8 8x0,5A (AWZ578 or LB4 4x0,5A (AWZ574 or AWZ576) + 65Ah  

4. Buffer power supply unit HPSB 13,8V/2x12V/2x3A/65Ah.

 

- HPS 2xRN500 (13,8V/12V) + 65Ah 

5. Buffer power supply unit HPSB 13,8V/2x12V/6x1A/65Ah.

 

- HPS 2xRN500 (13,8V/12V)+2xLB4 6x1A (AWZ575 or AWZ576) + 65Ah 

6. Buffer power supply unit HPSB 13,8V/2x12V/12x0,5A/65Ah.

 

- HPS 2xRN500 (13,8V/12V)+2xLB8 12x0,5A (AWZ578 or AWZ580) + 65Ah 

Summary of Contents for HPSB 7012E

Page 1: ...HPSB 7012E v 1 0 HPSB 13 8V 6A 65Ah Buffer switching power supply unit EN Edition 4 from 12 11 2013 Supercedes 3 from 16 09 2013...

Page 2: ...ply to devices requiring stabilised voltage of 12 V DC 15 The PSU provides voltage of U 13 8 V DC Current efficiency 1 Output current 6A 1A battery charge 2 Output current 5A 2A battery charge Total d...

Page 3: ...iption 1 PSU module 2 connectors see tab 2 3 green LED indicates AC power 4 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact of sabotage protection...

Page 4: ...www pulsar pl HPSB7012E 4 Fig 2 The view of the PSU...

Page 5: ...y LED indication AC diode indicating AC power status AUX diode indicating DC power status at the PSU output red normal status on failure off green normal status on failure off Sabotage protection TAMP...

Page 6: ...ees sufficient convectional air flow through ventilating holes of the enclosure Before installation prepare a PSU load balance 1 Output current 6A 1A battery charge 2 Output current 5A 2A battery char...

Page 7: ...o U 13 8V DC 9 After installing and checking proper working the enclosure can be closed 3 Operating status indication 3 1 LED indication of operating status The PSU is equipped with two diodes on the...

Page 8: ...t within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs o...