Pulsar HPSB 7012D Manual Download Page 2

 

 

2

 

 

Features: 

 

 

DC 13,8V/6A uninterruptible power supply  

 

fitting battery: 40Ah/12V  

 

wide range of mains supply: 176÷264V  

 

high efficiency 80% 

 

battery charging and maintenance control 

 

excessive discharging (UVP) protection 

 

jumper selectable battery charge current 1A/2A 

 

 

battery output full protection against short-circuit 
and reverse polarity connection  

 

LED indication  

 

protections: 

 

SCP short-circuit protection 

 

OVP overvoltage protection 

 

overvoltage protection (AC 

input

)  

 

against sabotage 

 

overload protection (OLP) 

 

 

CONTENTS: 
1. Technical description. 

1.1 General description 
1.2 Block diagram 
1.3 Description of PSU components and connectors. 
1.4 Specifications 

2. Installation. 

2.1 Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1 LED indication of operating status 

4. Operation and use. 

4.1 Overload or short circuit of the PSU output (SCP on) 
4.2 Disconnection of discharged battery 
4.3 Maintenance 

 

 
1. Technical description. 
 

1.1 General description. 
A buffer PSU is intended for an uninterrupted supply to devices requiring stabilised voltage of 12 V DC (+/-

15%). The PSU provides voltage of U=13,8 V DC. Current efficiency: 

 

1.  Output current 6,0A + 1,0A battery charge 
2.  Output current 5,0A + 2,0A battery charge  

Total device c battery: 7A max. 
 

In case of power decay, a battery back-up is activated immediately. The PSU is constructed based on the 

switch mode PSU, with high energy efficiency. The PSU is housed in a metal enclosure (colour RAL 9003) which 
can accommodate a 40Ah/12V battery. A micro switch indicates door opening (front cover). 

 

OPTIONAL POWER SUPPLY CONFIGURATIONS:  

(visualisation available at: 

www.pulsar.pl) 

 
1. Buffer power supply unit  HPSB 13,8V/4x1,5A/40Ah. 

- HPS  LB4 4x1,5A (AWZ576) + 40Ah 

2. Buffer power supply unit  HPSB 13,8V/6x1A/40Ah. 

- HPS  LB8 6x1A (AWZ579 or  AWZ580) + 40Ah 

3. Buffer power supply unit  HPSB 13,8V/12x0,5A/40Ah. 

- HPS 2xLB8 12x0,5A (AWZ578 or AWZ580) + 40Ah  
- HPS LB8 8x0,5A (AWZ578 or  LB4 4x0,5A (AWZ574 or AWZ576) + 40Ah  

4. Buffer power supply unit  HPSB 13,8V/2x12V/2x3A/40Ah. 

- HPS 2xRN500 (13,8V/12V) + 40Ah 

5. Buffer power supply unit  HPSB 13,8V/2x12V/6x1A/40Ah. 

- HPS 2xRN500 (13,8V/12V)+2xLB4 6x1A (AWZ575 or  AWZ576) + 40Ah 

6. Buffer power supply unit  HPSB 13,8V/2x12V/12x0,5A/40Ah. 

- HPS 2xRN500 (13,8V/12V)+2xLB8 12x0,5A (AWZ578 or AWZ580) + 40Ah 

Summary of Contents for HPSB 7012D

Page 1: ...HPSB 7012D v 1 0 HPSB 13 8V 6A 40Ah Buffer switching power supply unit EN Edition 1 st from 21 st of December 2011 Supercedes the edition ...

Page 2: ... voltage of 12 V DC 15 The PSU provides voltage of U 13 8 V DC Current efficiency 1 Output current 6 0A 1 0A battery charge 2 Output current 5 0A 2 0A battery charge Total device current battery 7A max In case of power decay a battery back up is activated immediately The PSU is constructed based on the switch mode PSU with high energy efficiency The PSU is housed in a metal enclosure colour RAL 90...

Page 3: ...odule 2 connectors see tab 2 3 green LED indicates AC power 4 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact of sabotage protection NC 7 Additional connector for LED indication 8 Ibat Selection jumper for charging current Ibat 1A Ibat 2A Legend jumper installed jumper removed Factory settings Ibat 1A jumper installed Tab 1 The components of the...

Page 4: ...4 Fig 2 The view of the PSU ...

Page 5: ...indication AC diode indicating AC power status AUX diode indicating DC power status at the PSU output red normal status on failure off green normal status on failure off Technical outputs TAMPER indicates enclosure opening microswitch NC contacts enclosure closed 0 5A 50V DC max Mechanical parameters tab 4 Enclosure dimensions 325 x 355 x 170 8 320 x 350 x 170 WxHxD Fixation se figure 2 Fitting ba...

Page 6: ...convectional air flow through ventilating holes of the enclosure Before installation prepare a PSU load balance 1 Output current 6 0A 1 0A battery charge 2 Output current 5 0A 2 0A battery charge Total device current battery 7A max As the PSU is designed for a continuous operation and is not equipped with a power switch therefore an appropriate overload protection shall be guaranteed in the power ...

Page 7: ...C 9 After installing and checking proper working the enclosure can be closed 3 Operating status indication 3 1 LED indication of operating status The PSU is equipped with two diodes on the front panel 4 Operation and use 4 1 Overload or short circuit of the PSU output SCP on In case of overload the output voltage is automatically shut off and so is the LED indicator The restoration of the voltage ...

Page 8: ...ty repairs at the earliest convenienve however not later that within 14 days from the delivery to the service centre of the manufacturer 7 The repair period mentioned in item 6 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 8 All the services rendered by force o...

Reviews: