Pulsar GREEN POWER plus HPSBOC 20A12E Manual Download Page 10

www.pulsar.pl                                                      HPSBOC20A12E                                                           

GREEN POWER plus

  

 

 

10

 

 

 

WEEE MARK 

 

According to the EU WEE Directive 

– It is required not to dispose of electric or 

electronic waste as unsorted municipal waste and to collect such WEEE separately. 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled 

according to the applicable law. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pulsar  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 
 

GENERAL WARRANTY CONDITIONS 

 

1. Pulsar (the manufacturer) grants a two-year warranty for the equipment,, 

counted from the device’s production 

date. 
2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the 
manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, 
unless such defects have been reported within the warranty period (item 1).  
3. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main 
office of the manufacturer.  
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description 
of the defect.   
5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest 
convenienve, however not later that within 14 days from the delivery to the service centre of the manufacturer.  
6. The repair period mentioned in item 5 may be prolonged, if there are no technical possibilities to carry out the 
repairs, or if the equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.  
7. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, 
exclusively.  
8. The warranty does not cover the defects of the equipment, resulting from: 
- reasons beyond the manufacturer's control, 
- mechanical damage, 
- improper storage and transport, 

use that violates the operation manual or equipment’s intended use 

- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical 
agents,  
- improper installation and configuration (in defiance with the manual), 
9. The warranty is void in any of the following circumstances: 
- construction changes  
- repairs carried out by any unauthorized service center 
- damage or removal of warranty labels 
- modifications of the serial number 
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined 
according to the wholesale prices suggested by the manufacturer on the day of purchase.  
11. The manufacturer takes no reponsibility for the defects that result from:  
- the damaging, malfunctioning or inability to operate the equipment 
- defects that result from using the equipment outside its stated specifications and operating parameters failing to 
abide by the recommendations and requirements contained in the manual, or the use of the equipment.  

 

Summary of Contents for GREEN POWER plus HPSBOC 20A12E

Page 1: ...HPSBOC 20A12E v 1 0 HPSBOC 13 8V 20A 65Ah OC Buffer switch mode power supply unit with technical outputs EN Edition 1 from 04 03 2015 Supercedes edition GREEN POWER plus...

Page 2: ...tallation procedure 3 Operating status indication 3 1 LED indication of operating status 3 2 Technical outputs 4 Operation and use 4 1 Overload or short circuit of the PSU output SCP on 4 2 Disconnect...

Page 3: ...tput indicating DC absence PSU failure relay type 6 LoB output indicating battery low voltage relay type 7 EPS AC absence technical output OC type 8 PSU output indicating DC absence PSU failure OC typ...

Page 4: ...2 Description of PSU components and connectors fig 3 Element no Fig 3 Description 1 PSU module 2 TAMPER contact sabotage protection NC Fig 3 The view of the PSU 1 4 Specifications electrical parameter...

Page 5: ...indicating unwanted opening of the PSU s enclosure a microswitch NC contacts enclosure closed 0 5A 50V DC max LED indication AC diode indicating AC power status DC diode indicating DC power status at...

Page 6: ...llation 2 1 Requirements The buffer PSU shall be mounted by a qualified installer with appropriate permissions and qualifications for 230V AC installations and low voltage installations required and n...

Page 7: ...and fully operational shock protection circuit is UNACCEPTABLE It can cause a device failure or an electric shock 4 Connect the receivers cables to the terminals V V of the PSU module 5 Connect the po...

Page 8: ...ut is connected to ground L level 0V In case of absence of DC voltage at the output e g short circuit the output is switched into high impedance state hi Z relay output In case of a failure the contac...

Page 9: ...ipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 9 5 V at the battery terminals will cause battery disconnection 4 3 Maintenance Any...

Page 10: ...thin 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if...