Pulsar Green Power HPSB 20A12C Manual Download Page 5

www.pulsar.pl

                                                               

HPSB20A12C                                                    

GREEN POWER

 

 

 

5

 

W

H

D

1.4 Specifications:  

      - electrical parameters (tab.2) 
      - mechanical parameters (tab.3) 
      - operation safety (tab.4) 
      - operating parameters (tab.5) 

 

      

Table 2. Electrical parameters  

PSU type 

A (EPS - External Power Source) 

Mains supply 

176÷264V AC  50Hz 

Current up to 

1,5A@230VAC max. 

Supply power 

276W max.  

Efficiency 

85% 

Power factor PF 

>0,95 @230V AC 

Output voltage 

11V÷ 13,8V DC – buffer operation 
9,5V÷13,8V DC – battery-assisted operation 

Output current t

AMB

<30°C 

18A + 2A battery charge - refer to chart 1 
16A + 4A battery charge - refer to chart 1 
12A + 8A battery charge - refer to chart 1 

Output current t

AMB

=40°C 

12A + 2A battery charge - refer to chart 1 
10A + 4A battery charge - refer to chart 1 
 6A + 8A battery charge - refer to chart 1 

Voltage adjustment range 

12

÷14VDC 

Ripple  

120mV p-p max. 

Current consumption by PSU systems 

170mA 

Battery charge current 

2A/4A/8A- jumper selectable 

Short-circuit protection SCP 

electronic, automatic return 

Overload protection OLP 

105-150% of the PSU power, automatic return 

Battery circuit protection SCP and reverse  
polarity connection 

melting fuse 30A 

Surge protection 

varistors 

Overvoltage protection OVP 

>16V (

activation requires disconnecting the load or 

supply for about 20 s.) 

Excessive discharge protection UVP 

U<9,5V (

± 5%) – disconnect of connection battery  

Sabotage protection: 
- TAMPER output indicating enclosure opening 

 
- microswitch, NC contacts (enclosure closed), 
0,5A@50V DC (max.) 

LED indication:  
- AC diode indicating AC power status 
- DC diode indicating DC power status at 
the PSU output 

 
- red, normal status 

– on, failure: off 

- green, normal status 

– on, failure: off 

 
      Table 3. Mechanical parameters  

Enclosure dimensions 

400 x 350 x 90+8 [mm] (WxHxD) 

Fixation 

se figure 2 

Fitting battery 

17Ah/12V (SLA) max. 
185x170x80mm (WxHxD) max  

Net/gross weight 

4,0/4,3 kg 

Enclosure  

Steel plate DC01, thickness: 1,0mm, colour: RAL 9003 

Closing 

Cheese head screw x 2 (at the front), lock assembly possible 

Connectors 

Power supply: 

Φ0,63-2,50 (AWG 22-10) 

Outputs: Φ0,63-2,50 (AWG 22-10),  
Battery output BAT: 

Ф6/2,5mm

2

 

TAMPER output: wires  

Notes 

The enclosure does not touch the assembly surface so that cables can be led. 
Forced cooling - built-in fan. 

       

       
 
 
 
 
 
 
 
 

Summary of Contents for Green Power HPSB 20A12C

Page 1: ...HPSB 20A12C v 1 0 HPSB 13 8V 20A 17Ah Buffer switch power supply unit EN Edition 1 from 04 03 2016 Supercedes the edition ...

Page 2: ...tions 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 4 Operation and use 4 1 Overload or short circuit of the PSU output SCP on 4 2 Disconnection of discharged battery 4 3 Maintenance 1 Technical description 1 1 General description A buffer PSU is intended for an uninterrupted supply to devices requiring stabilised voltage of 12V DC 15 The PSU provides vol...

Page 3: ...U module Connectors PSU L N power supply connector 230V AC Protection connector PE V V DC power output B B battery output green LED indicates AC power P1 potentiometer output voltage adjustment Battery outputs red black TAMPER contact of sabotage protection NC Additional connector for LED indication Selection jumper for charging current Ibat 2 A Ibat 4A Ibat 8A Description jumper installed jumper ...

Page 4: ...www pulsar pl HPSB20A12C GREEN POWER 4 Fig 2 The view of the PSU ...

Page 5: ... 105 150 of the PSU power automatic return Battery circuit protection SCP and reverse polarity connection melting fuse 30A Surge protection varistors Overvoltage protection OVP 16V activation requires disconnecting the load or supply for about 20 s Excessive discharge protection UVP U 9 5V 5 disconnect of connection battery Sabotage protection TAMPER output indicating enclosure opening microswitch...

Page 6: ...on 2 1 Requirements The buffer PSU shall be mounted by a qualified installer with appropriate permissions and qualifications for 230V AC installations and low voltage installations required and necessary for a given country The device shall be mounted in confined spaces according to the environment class II with normal air humidity RH 90 max without condensation and the temperature from 10 C to 40...

Page 7: ...odule 5 Connect the power 230V 6 Check the PSU output voltage the PSU voltage without load should amount to U 13 8V DC 7 Connect the battery mind the colours battery output V BAT cable red battery output 0V BAT cable GND black 8 Check the PSU operation indicator green LED on the power supply module 9 After installing and checking proper working the enclosure can be closed 3 Operating status indica...

Page 8: ...in 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of the manufa...