Pulsar GD400BN Operator'S Manual Download Page 12

11

Service and Maintenance

Good maintenance is essential for safe, economical operation and long service life. The maintenance schedule is below:

 

Maintenance Cycle

 

 

Item

 

 

 

 

 

 

 

 

 

 

Engine oil

 

 

 

 

 

 

Replace

 

 

 

 

         

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Cleaner
Element 

 

Inspection

 

 

 

 

 

Clean

 

 

 

 

 

Replace

 

 

 

 

         

 

Clean

 

 

 

 

 

 

Clean - Adjust 

 

 

 

 

 

 

 

Clean

 

 

 

 

 

 

 

 

 

 

 

 

 

Check - Adjust 

 

 

 

 

 

 

 

Clean

 

 

 

 

 

 

Fuel Hose

 

Inspection

 

                  

Every Two Years

 

Remove 
Carbon 
Deposit **

 

 

Check - Fill

** These tasks should be completed by an authorized Pulsar service center. 

Every 125 hours 

Cylinder Head, Piston 

Fuel Tank and Fuel
Filter **

Valve Clearance **

Spark Arrester

Spark Plug

Carburetor Float
Bowl   

Each
Week

Break-In
Maintenance at
1 Month or
20 Hours Use 

Quarterly
Maintenance is
every 90 Days or
50 Hours Use

Annual
Maintenance
or 100 Hours
Use 

Summary of Contents for GD400BN

Page 1: ...tate of California to cause cancer birth defects or other reproductive harm support pulsar products com 866 591 8921 STOP DO NOT RETURN TO STORE HAVE QUESTIONS OR NEED SERVICE FUEL SOURCE CIRCUIT BREA...

Page 2: ...e or more of the notices below Safety Warnings alert you to potential hazards that could cause death injury or damage to property The decals show one of four words DANGER WARNING CAUTION and NOTICE De...

Page 3: ...bon Monoxide can KILL YOU in minutes Avoid running the generator in the rain or very high condensing humidity Never smoke or allow any heat source near the generator while refueling it Always shut dow...

Page 4: ...tion practices Lifting Handle Left Enclosure Control Panel Recoil Start Spark Plug Access Rear Panel Muffler Fuel Tank Cap FUEL SOURCE CIRCUIT BREAKER INDICATOR LIGHT LOW IDLE PARALLEL CONNECTION TO A...

Page 5: ...4 Control Panel FUEL SOURCE CIRCUIT BREAKER INDICATOR LIGHT LOW IDLE PARALLEL CONNECTION TO AVOID DAMAGE DO NOT CONNECT OR DISCONNECT PARALLEL CABLES WHILE THE UNIT IS RUNNING MULTI SWITCH...

Page 6: ...OR LIGHT Overload Indicator Red When the overload indicator illuminates the generator has detected excess electrical load and the circuit breaker may open trip If the overload indicator illuminates an...

Page 7: ...surface 2 Unscrew the knob to remove oil access cover 3 Unscrew oil dipstick CIRCUIT BREAKER Gasoline is highly flammable and toxic You must read and understand ALL safety instructions before fueling...

Page 8: ...ting propane to your generator Never bring a propane tank inside the home or any enclosed structure After connection check for leaks Open the tank supply valve apply soapy water to the gas fittings an...

Page 9: ...engine start FUEL SOURCE CIRCUIT BREAKER INDICATOR LIGHT LOW IDLE PARALLEL CONNECTION TO AVOID DAMAGE DO NOT CONNECT OR DISCONNECT PARALLEL CABLES WHILE THE UNIT IS RUNNING SELECTOR SWITCH STEP 2 Let...

Page 10: ...PG valve completely Fuel source switch to LPG FUEL SOURCE CIRCUIT BREAKER INDICATOR LIGHT LOW IDLE PARALLEL CONNECTION TO AVOID DAMAGE DO NOT CONNECT OR DISCONNECT PARALLEL CABLES WHILE THE UNIT IS RU...

Page 11: ...IRCUIT BREAKER INDICATOR LIGHT LOW IDLE PARALLEL CONNECTION TO AVOID DAMAGE DO NOT CONNECT OR DISCONNECT PARALLEL CABLES WHILE THE UNIT IS RUNNING SELECTOR SWITCH Using the Generator Operating Range o...

Page 12: ...ust Clean Check Adjust Clean Fuel Hose Inspection Every Two Years Remove Carbon Deposit Check Fill These tasks should be completed by an authorized Pulsar service center Every 125 hours Cylinder Head...

Page 13: ...til all oil has drained wipe up any spills Refill crankcase with 12 ounces 0 35l 10w 30 engine oil check with dipstick Tighten oil dipstick replace oil access cover and tighten the knob Air Filter A d...

Page 14: ...lter element and squeeze gently to distribute the oil film evenly 5 Reinstall the air filter element in reverse order 1 Remove fuel tank cap and fuel tank filter screen 2 Clean fuel tank filter screen...

Page 15: ...tank leave some expansion space Do not run the generator while transporting Protect from direct sunlight Do not transport the generator across rough terrain Engine No Start Fuel System 1 There is no...

Page 16: ...plash Lubrication Splash Lubrication Noise dB at 7m 62 63 Generator Rated Power kW 1 8 2 8 Rated Voltage V 120 120 Rated Frequency Hz 60 60 Rated Power Factor 1 1 Phase Number Single Phase Single Phas...

Page 17: ...16 Electrical Schematic 120V 60Hz Electrical Schematic...

Reviews: