background image

3

INTRODUCTION

Date of Purchase: 

Model Number: 

Serial Number:

Thank  you  for  purchasing  this  superior  quality  portable  generator  from  Pulsar 

P

roducts 

I

Inc.  When  operating  and 

maintaining this product as instructed in this manual, your generator will give you many years of reliable service. 

Product Specifications:

This generator is an engine-driven, revolving field, alternating current (AC) portable generator. It is designed to supply 
electrical power to operate tools, appliances, camping equipment, lighting, or serve as a back up power source during 
power outages.

The emissions control system for this generator is compliant with all standards set by the U.S. Agency.

How to contact us:

To order parts, receive warranty assistance, or other services inquiries, you can contact us by internet at www.pulsar-

products.com or write to us at:

AC Output

Rated Wattage

800

0W (

8.0

kW)

Rated Voltage

120V/240V

Rated Frequency

60Hz

Rated Ampere

66.6

A / 

33.3

A

Maximum Output

10

kVA

Record the following information bellow for service or warranty assistance.

PULSAR PRODUCTS INC

 

5721 E. SANTA ANA AVE. 

ONTARIO. 91761

SAVE THIS MANUAL FOR FUTURE REFERENCE

This manual contains important information regarding safety, operation, and maintenance.  

Engine

420cc OHV, 4 Stroke, Air Cooled

Engine Oil

10W30 - 38oz (1

.1

L)

Fuel Tank

6.6 Gal (25L) Unleaded Gasoline

Item Number: 

GAS

LPG

7

0

0

0W (

7

.0kW)

120V/240V
60Hz

58.3

A / 2

9.1

A

9

kVA

1-866-591-8921

Summary of Contents for G10KBN

Page 1: ...r www pulsar products com OPERATOR S MANUAL Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Model G10KBN ...

Page 2: ...tor to an Electrical System 13 Operation 14 How to Stop Engine 15 Grounding the Generator How to Start Engine 14 Receptacles and Extension Cords 15 Don t Overload Generator 16 Wattage Reference Guide 17 Cold Weather Operation 18 Maintenance 19 Maintenance Schedule 19 Engine Maintenance 21 Maintaining Fuel Valve 22 Changing Oil 20 How to Store 23 Troubleshooting 24 Diagrams 25 TABLE OF CONTENTS War...

Page 3: ...generator is compliant with all standards set by the U S Agency How to contact us To order parts receive warranty assistance or other services inquiries you can contact us by internet at www pulsar products com or write to us at AC Output Rated Wattage 8000W 8 0kW Rated Voltage 120V 240V Rated Frequency 60Hz Rated Ampere 66 6A 33 3A Maximum Output 10kVA Record the following information bellow for ...

Page 4: ...f serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigue nausea fainting Never use indoors in a covered area or in a confined space even if doors and windows are open Keep exhaust from this unit from entering a confined area t...

Page 5: ... If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the spark plug wire and make sure the fuel tank is empty with the fuel shutoff valve turned to the off position WARNING Never exceed generator s wattage amperage capacity This could damage the generator...

Page 6: ...enerator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source WARNING Generator must be properly grounded to prevent electrocution Never handle the generator electronic devices or any cord while standing in water while barefoot or when hands or feet are wet Always keep the generator dry Never operate generator in rain or under wet conditions Us...

Page 7: ...Volt AC 50 Amp receptacle NEMA L14 50R G 12 Volt 8 3 Amp Output For charging batteries only H No Flat Foam Filled Tires I Fuel Tank Vapor Vent J Fuel Gauge J Generator Frame K Choke Lever L Air Filter M Handles Grip N Support Leg Foot O Fuel Tank Vapor Vent P Fuel Fill Cap Q Fuel Valve ON OFF R Recoil Starter Grip S Oil Fill Dipstick I P A B C E F O J K Q R L M N G D H S ...

Page 8: ...ged 3 Cut down the sides of box being careful to avoid hitting the generator 4 Leave generator on box to install wheel assembly Packing List Check all loose parts to the following list Contact your dealer if any loose parts are not included Description Qty Generator 1 Operator s Manual 1 Products Warranty Card Toolkit Spark Plug Wrench Combination Wrench 1 1 2 2 Washer 2 Funnel 1 Handles 2 Bushing...

Page 9: ...ing M8 screws 2 and nuts Installing Support Leg See fig 2 Parts needed 2 wheels 2 axles 2 hair pins and 2 washers Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the frame Secure the wheel assembly by reinserting a hair pin through hole at the end of the wheel axle and pressing until it locks into place Repeat pro...

Page 10: ...n removing the battery for replacement Remove the nut and bolt first from the negative Black post then from the positive Red post being careful not to short across the terminals Always abide by the safety warnings provided with the battery Remove the battery and dispose of it according to your local and state regulations Be careful not to short across the terminals when installing Shorting the ter...

Page 11: ...er If you get electrolyte contact with your eye rinse immediately with clean water and seek medical attention NOTICE If the Generator is stored for over six months the battery will need to be removed and charged Pb Place generator on a level surface Remove the crankcase dipstick to ensure you do not overfill the engine Insert a funnel into the crankcase dipstick hold and carefully add 4 Cycle engi...

Page 12: ...eath to electric utility workers WARNING This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to an Electrical System a transfer switch The power from the generator must be isolated from the circuit breaker or alternative power source If connecting generator to a building s electrical system for standby power y...

Page 13: ...HOT For electric start Push and hold the engine START ON OFF switch in the START position Do not hold the START 2 START Connect the gas pipe to the intake nozzle of regulator Open the valve of LPG bottle SKIP THIS IF THE ENGINE IS WARM OR HOT For electric start Push and hold the engine START ON OFF switch in the START position Do not hold the START ON OFF switch in the Start position for more than...

Page 14: ...acles Battery Charger for Electric Starter How to Stop Engine See fig 15 18 MUST 2 2 Four 120 Volt AC 20 Amp receptacles 20 2 0 Volt AC 0 Amp receptacle NEMA L 0 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30 12 Volt 8 3 Amp Output For charging batteries only 120 Volt AC 20 Amp receptacle This receptacle has a 20 Amp push to reset circuit breaker to protect against overload Each socket i...

Page 15: ...ople to lift Lift and lower with your legs by bending at the knees not your back to avoid injury Don t Overload Generator Make sure you can supply enough rated watts and surge watts for all electronic devices connected to the generator Rated watts refer to the power a generator must supply to keep a device running Surge watts refer to the power a generator must supply to start an electronic device...

Page 16: ...ric Blanket 400 400 Space Heater 1800 1800 Kitchen Blender 300 900 Toaster 2 slice 1000 1600 Coffee Maker 1500 1500 Electric Range 1 element 1500 1500 Dishwasher 1500 3000 Electric Oven 3410 3410 Electric Water Heater 4000 4000 Laundry Room Iron 1200 1200 Washing Machine 1150 3400 Gas Clothes Dryer 700 2500 Electric Clothes Dryer 5400 6750 Wattage Reference Guide Wattages listed are just approxima...

Page 17: ...er Use a wire brush to clean battery terminals if corroded Connect the Battery Charging Cable Connection Plug to the 12 Volt D C Receptacle Connect the red cable clamp to the positive battery terminal Connect the black cable clamp to the negative battery terminal Start generator engine Let engine run while battery charges Battery is considered fully charged when the gravity of its fluid is 1 260 o...

Page 18: ...e Store unit in a clean and dry area WARNING After First 5 Hours Change Oil After 8 Hours or Daily Clean Debris Check Engine Oil Level Annually 25 hr Use Check and Clean Air Cleaner Change Engine Oil Service more often under dirty or dusty conditions Check Muffler and Spark Arrester Annually 100 hr Use Service Spark Plug Replace with NGK BP6ES Champion N9YC or equivalent Service Fuel Valve Inspect...

Page 19: ...ures determine the proper oil viscosity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Carefully add SAE 10W 30 to empty reservoir until the oil reaches the outer edge of the oil fill hole Crankcase Dipstick hole Replace crankcase dipstick Oil drainage plug Fig 21 Oil Fill Dipstick 22 4 14 32 50 68 86 104 30 20 10 0 10 20 30 40 SAE 30 10W 30 Sy...

Page 20: ...ary Reinstall spark plug and tighten to Torque 22 0 26 9 Nm 16 20 ft lb Reconnect spark plug wire If spark plug is worn replace only with an equivalent replacement part Spark plug should be replaced annually BOSCH F7TC NGK BP6ES CHAMPION N9YC or Equivalent To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove dirt from filter by tapping on it o...

Page 21: ... from the tank Turn the fuel valve to the ON position Hi High Altitude Operation At high altitude the standard carburetor air fuel mixture will be too rich Performance will decrease and fuel consumption will increase A very rich mixture will also foul the spark plug and cause hard starting Operation at an altitude that differs from that at which this engine was certified for extended periods of ti...

Page 22: ...lowly pull the recoil Starter until you feel the engine build compression When you feel resistance Leave the Engine in this state as this will prevent any corrosion on the cylinder walls if stored for a long period of time Storage and Transportation of the Generator See Fig 24 Remove any debris that has collected on the generator and around the muffler and control panel Use a brush or vacuum to re...

Page 23: ... fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Dead battery 15 Engine has flooded 1 Turn switch to ON 2 Replace Air filter 3 Clean or replace fuel filter 4 Replace fuel 5 Reconnect spark plug wire 6 Replace spark plug 7 Drain fuel tank and replace fuel 8 Turn fuel valve to ON position ...

Page 24: ...DIAGRAMS 24 ...

Page 25: ...tor components parts and labor Year 2 Limited coverage on generator engine components parts only Personal use means personal residential household use or recreational use by the retail consumer Commercial use means all other uses including commercial construction or other income producing purposes Once a generator has been used for commercial purposes it shall thereafter be considered as a commerc...

Page 26: ...original purchaser in the United States Canada or Mexico Refurbished used demonstration or floor models are not covered by this warranty Products purchased from on line auction websites such as ebay are not covered under this warranty Products used for commercial use are not covered under this warranty How to Obtain Warranty Service Take the original receipt and product to the place of purchase or...