PULSAR MEASUREMENT
11
ECHO PROCESSING
Description
DATEM (
D
igital
A
daptive
T
racking of
E
cho
M
ovement)
Technology
Ultrasonic and FMCW Radar
PROGRAMMING
On-board programming
By integral keypad
Programming security
Via passcode (user selectable and adjustable)
Programmed data integrity
Via non-volatile RAM
PC Programming
Via RS232 using supplied software
Remote programming
via RS232 using optional hand-held calibrator
SUPPLY
Power Supply
115 VAC +5% / -10%
50/60 Hz,
230 VAC +5% / -10%
50/60 Hz,
DC 10 - 28V
10W maximum power (typically 5W)
Mains fuse (F1)
100 mA T at 115V AC
DC (Battery) (F2)
1A Thermal (self-resetting after power removed). Not
user replaceable
Transducer (F3, F5)
Little fuse 242 series 100mA Part No. 0242.100. This
fuse is not user replaceable and has a 4000A
breaking capability to comply with certification of the
Exm version of dB series transducers.
REMOTE COMMUNICATOR
Power Supply
Power supplied via BlackBox RS232 interface.
Pulsar Measurement operates a policy of constant development and
improvement and reserve the right to amend technical details, as necessary.