Starting Operation

POWERING ON AND IMAGE SETTING

•  Open the lens cover 

(7)

. Secure the cover with to the strap using the built-in 

magnet in the cover.

•  Press the ON/OFF button 

(5)

 briefly to turn on the device.

•  Adjust the eyepiece diopter ring 

(1)

 until the symbols in the display are 

sharp. 

•  Rotate the lens focus knob 

(6)

 to focus on the object being observed.

•  Enter the main menu with a long press of the MENU button 

(3)

 and select the 

desired calibration mode: manual (M), semi-automatic (SA) or automatic (A).

• 

Calibrate the image by briefly pressing the ON/OFF button 

(5)

 (if the SA or M 

calibration mode has been selected). Close the lens cover when calibrating 

manually. 

• 

Select the desired observation mode (“Forest”, “Identification”, “Rocks”, 

“User”) by briefly pressing the UP button 

(4)

. User mode allows you to change 

and save user brightness and contrast settings in the quick menu.

•  Enter the main menu with a long press of the MENU button 

(3)

 and select the 

appropriate colour palette (for more details see the Main menu functions 

section in the full version of the manual).

• 

Activate the quick menu by briefly pressing the MENU button 

(3)

 to adjust the 

brightness, contrast and smooth digital zoom of the display (see the Quick 

Menu Functions section of the full version manual for details).

•  Upon completion of use turn the device off by a long press of the ON button 

(5)

.

Components and controls

1.  Eyepiece diopter ring

2.  DOWN/LRF button 

3.  MENU button 

4.  UP/ZOOM button 

5.  Power ON/

Calibration button  

6.  Lens focus knob

7.  Lens cover

8.  Adaptor mount 

for tripod

9.  USB Type-C 

connector

10. 

Laser rangefinder

ENGLISH

1

Summary of Contents for AXION LRF XQ38

Page 1: ...Quick Start Guide AXION LRF XQ38 Thermal Imaging Scope...

Page 2: ...tung f r ausf hrliche Informationen zum Ger t herunter https www pulsar nv com glo products 33 thermal imaging scopes axion xq lrf Vorsicht Wenn andere als die hier angegebenen Bedienungs oder Justier...

Page 3: ...LRF Imageur thermique AXION LRF W rmebildger t AXION LRF Monocular t rmico AXION LRF Termovisore AXION LRF AXION LRF 1 6 7 12 13 18 19 24 25 30 21 36 ENGLISH FRAN AIS DEUTSCH ESPA OL ITALIANO Quick S...

Page 4: ...ode Forest Identification Rocks User by briefly pressing the UP button 4 User mode allows you to change and save user brightness and contrast settings in the quick menu Enter the main menu with a long...

Page 5: ...e the rangefinder scan mode Menu navigation down left Deactivate the rangefinder Battery Pack Charging The AXION LRF XQ thermal imagers come with APS 5 rechargeable lithium ion battery APS 5 batteries...

Page 6: ...from the charger Defective battery It is forbidden to use the battery LED indication 13 in the standby mode Battery Level Battery level is from 0 to 25 Battery level is from 26 to 50 Battery level is...

Page 7: ...riefly A red mark appears on the display Place the rangefinder s reticle on the target Press the DOWN 2 button briefly to measure the distance to the object once The measurement results are displayed...

Page 8: ...ixels 1024x768 Operational characteristics Power Supply V 3 4 2 V Battery Type APS 5 Li ion Battery Pack Capacity 4900 mAh Nominal output voltage DC 3 7 V External power supply 5 15 V USB Type C Batte...

Page 9: ...al Imager APS 5 rechargeable battery 2 lock cover of APS 5 battery Battery Pack Charger Power Adapter USB Type C Cable Carrying case Hand strap Quick User Manual Lens cleaning cloth Warranty sheet Ada...

Reviews: