Pulsar AWT830 Assembly Instructions Download Page 2

 

EN 
1. General description. 

 

            

1.1. Destination. 

The 

AWT830,

  transformer  is  designed  for  the  supply  of  equipment  requiring  the  AC  voltage:  U1.  The  power  of 

devices connected to the terminals must not exceed the power of the transformer.

 

 

1.2. Electrical diagram. 

 

 

1.3. Description of elements and power supply connectors

 

 

 

 
 

 
 
 

 

2. Installation. 

The safety transformer must be installed by a qualified installer, holding the relevant certificates, required and 

necessary in the particular country for connecting (interfering with) the 230 V systems and low-voltage installations.  

 

           The transformer should be installed indoors (controls cabinets, casings), where air humidity is 
normal (RH=90% max. without condensation) and temperature in the range of -10°C to +40°C.  

 

1. Connect the transformer wires to the device.  

    Remarks:

 Connect the required voltage U1 for the device. The power of connected devices must not exceed the 

power of the transformer. 

2. Connect the transformer to 230 V outlet. The transformer should be installed in a manner and location that the flow of 
air around the transformer was free. 
3. Optionally perform other connections that are required for the type of device / system.  

      

Remarks:

 according to the requirements and  recommendations of the producer. 

4.  Start the system (switch on ~230 V), adjust or configure: according to procedure of the producer’s system

.

 

 
3. Parametry techniczne / Technical data. 

Tab 1.

 

PARAMETRY 

TECHNICZNE 

TECHNICAL 

DATA 

 

Napięcie zasilania 

 

Power supply voltage 

230 V, 50Hz 

(-15%/+10%) 

Napięcie wyjściowe 

U1 

Power supply voltage 

U1 

Tab. 2 

Prąd wyjściowy nominalny 

I1 

Nominal output current 

I1 

Tab. 2 

Temperatura pracy / 

Klasa cieplna 

Operating temperature / 

Heat class 

-10ºC÷40ºC 

Ta 40B 

Wilgotność względna  RH – max. 

Relative humidity RH –max. 

90 [%] 

Wymiary szer x wys x głeb (S1,S2) 

 

Dimensions W x H x D (S1,S2) 

 

88 x 54 x 60  mm 

Waga netto 

 

Net Weight  

 

0,61 [kg, +/-10g]  

Waga brutto 

 

Gross Weight  

 

0,65 [kg, +/-10g] 

Element 

Description 

L-N 

Primary circuit connector,  230 V supply connector 

COM-U1 

Secondary winding,  output voltage U1 

fuse 