background image

 

The ARAW45 fan 

 

 
 
 

 
 

 
 
 

 

Cable glands and protection tubes 

 
Wires can be introduced in three ways: 

a) 

- Through rubber grommets, 

b) 

- Using the MM019/MM020 protection tubes, 

c) 

- Using the MM019/MM020 protection tubes and the ARAP16P/ARAP21P cable glands. 

 

 
 

 
 

 

 
 

 
 

 
 

 

 
5. Specifications 

 
 

 

SPECIFICATIONS 

 

Fitting battery 

17Ah/12V 

Tampering protection 

1x – against unwanted opening of the enclosure 

Max. load of TAMPER output 

500mA@50VDC 

Enclosure: IP 

IP 20 

Operation temperature 

-10ºC÷40ºC 

Relative humidity RH – max. 

90 [%] 

Internal dimensions 

(W x H x D) 

390 x 115 x 265  

[-/+2] [mm] 

Materials 

Sheet metal DC01, 1,0mm thick + front panel thickness: 

1,5mm 

Rust protection 

Colour: RAL 9005 BLACK 

Use 

inside 

Net weight 

~4,40  [kg] 

Gross weight 

~4,95  [kg] 

Declarations, warranty 

CE,  2 year from the production date 

 

 

 

PRODUCENT / PRODUCER 

 

Pulsar  

Siedlec 150,  

32-

744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

 
 

Summary of Contents for ARAD3S

Page 1: ...re can accommodate a 17Ah 12V battery and it features tampering protection against unwanted opening To enable leading cables into the enclosure one can buy a cable protection conduit of any length and a cable gland The conduits and the cable glands are available at the following codes 1 ARAP16P cable gland inside diameter 16 mm connection between the protection conduit and the enclosure 2 ARAP21P ...

Page 2: ...s The ARAD3S enclosure can be mounted in two ways 1 Mounting without the ARAS450 rails no extension slide the front part is the load bearing part of the enclosure This method of installation is dedicated for economic versions with a load capacity of up to 5 kg ...

Page 3: ...tally and its length between the front and rear RACK profile is properly adjusted 2 2 Mount the ARAD enclosure on fully extended ARAS rails using 6xM4 screws complete with ARAS rails Tighten the screws from the inside The enclosure is mounted in the front of the RACK rails using 4xM6 screws 4 Accessories Power supplies PS PSB PSBOC series Transformers of the following series TOR TRP TRZ Empty moun...

Page 4: ... Max load of TAMPER output 500mA 50VDC Enclosure IP IP 20 Operation temperature 10ºC 40ºC Relative humidity RH max 90 Internal dimensions W x H x D 390 x 115 x 265 2 mm Materials Sheet metal DC01 1 0mm thick front panel thickness 1 5mm Rust protection Colour RAL 9005 BLACK Use inside Net weight 4 40 kg Gross weight 4 95 kg Declarations warranty CE 2 year from the production date PRODUCENT PRODUCER...

Reviews: