background image

 

2.

 

Mounting with the ARAS… rails - full extension slide of the RACK cabinet, rails of the ARAS… series are the load-

bearing part of the enclosure. Dedicated for up to 30kg load. 

             

2.1.

 

Mount cage nuts for M6 screws in the RACK cabinet, as shown in Figure below, and mount the ARAS rails 

(depending on the depth of the RACK cabinet). Make sure that the rail is correctly mounted horizontally and its 

length between the front and rear RACK profile is properly adjusted. 

 

 
 

 

 
 

 
 

 
 
 

 

 

2.2.

 

Mount the ARAD enclosure on fully extended ARAS rails using 6xM4 screws (complete with ARAS rails). 

Tighten the screws from the inside. The enclosure is mounted in the front of the RACK rails - using 4xM6 screws. 

 

 

 

 

4. Accessories:

 

 

 

Power supplies PS…/PSB…/PSBOC… series 

Transformers of the following series TOR/TRP/TRZ 

 

 

Empty mounting                     Empty mounting            Enclosed power supply             Transformers                   Transformers                                                                                                                        

plate                    PS.., PSB.., PSBOC.. series        units TOR… series                TRP… series                  TRZ 20/40 series 

 

Summary of Contents for ARAD2

Page 1: ...e enclosure can accommodate a 7Ah 12V battery and it features tampering protection against unwanted opening To enable leading cables into the enclosure one can buy a cable protection conduit of any length and a cable gland The conduits and the cable glands are available at the following codes 1 ARAP16P cable gland inside diameter 16 mm connection between the protection conduit and the enclosure 2 ...

Page 2: ...ons The ARAD2 enclosure can be mounted in two ways 1 Mounting without the ARAS rails no extension slide the front part is the load bearing part of the enclosure This method of installation is dedicated for economic versions with a load capacity of up to 5 kg ...

Page 3: ...y mounted horizontally and its length between the front and rear RACK profile is properly adjusted 2 2 Mount the ARAD enclosure on fully extended ARAS rails using 6xM4 screws complete with ARAS rails Tighten the screws from the inside The enclosure is mounted in the front of the RACK rails using 4xM6 screws 4 Accessories Power supplies PS PSB PSBOC series Transformers of the following series TOR T...

Page 4: ... Max load of TAMPER output 500mA 50VDC Enclosure IP IP 20 Operation temperature 10ºC 40ºC Relative humidity RH max 90 Internal dimensions W x H x D 390 x 70 x 395 2 mm Materials Sheet metal DC01 1 0mm thick front panel thickness 1 5mm Rust protection Colour RAL 9005 BLACK Use inside Net weight 5 20 kg Gross weight 5 95 kg Declarations warranty CE 2 year from the production date PRODUCENT PRODUCER ...