GREEN POWER CCTV PoE

 

 

 

 

1.2.  Block diagram. 

 

Fig. 1. Block diagram of the PSU. 

 
1.3.  The description of components and connectors of the PSU. 

Table 1. 

Component No. 

[Fig. 2] 

Description 

[1], [10] 

LED optical indication: 
green L

IN

   – 

indication of voltage at the IN input

 

red L

AC

  – 

AC voltage indication

 

red L

FPS

 – 

FPS failure indication

 

[2] 

Connector: 
IN –
 

power supply of the module (factory setting

AC – 230V 

mains supply indication input

 

[3] 

F1 

÷ 

F8 

fuses in the 

AUX1 ÷ AUX8 (+), F500mA circuits

 

[4] 

Jumper to select melting fuse or PTC polymer fuse

 

[5] 

Green LED L1 ÷ L8 - 

voltage indication at the AUX outputs (during normal operation, 

these LEDs are on)

 

[6] 

Network outputs (Et power supply) – for camera connection. 

[7] 

Network outputs (Ethernet) 

[8] 

FPS 

– 

technical output indicating failure – OC type

 

[9] 

FPS

 – 

technical output indicating failure – relay type

 

[11] 

Optional, external optical indication connector (factory setting

[12] 

PE – grounding the shield of the RJ45 connectors (factory setting) 

Table 1. 

The description of components of the 

PoE module. 

 

Fig. 2. Components arrangement. 

Summary of Contents for 54V/8x03A/4x7Ah

Page 1: ...POE084824B v 1 0 PoE 54V 8x0 3A 4x7Ah Switch mode buffer power supply unit for CCTV EN Edition 1 from 26 11 2013 Supersedes the edition GREEN POWER CCTV PoE...

Page 2: ...aintenance 1 Technical description 1 1 General description The PSU is designed for supply of up to 8 webcams requiring stabilized voltage of 48V DC 15 The PSU supplies voltage of 54V DC and total curr...

Page 3: ...ation input 3 F1 F8 fuses in the AUX1 AUX8 F500mA circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L8 voltage indication at the AUX outputs during normal operation these LED...

Page 4: ...black 6 TAMPER microswitch contacts of antisabotage protection NC Tab 2 Components of the PSU see Fig 3 1 4 Technical parameters electrical parameters Table 3 mechanical parameters Table 4 safety of...

Page 5: ...ical parameters Table 4 Enclosure dimensions 300 x 407 x 126 mm WxHxD Mounting See Fig 3 Battery housing 4x7Ah 12V SLA max Net weight 4 71kg 5 01kg Enclosure DC01 steel plate 1 0mm RAL 9003 Closing Cy...

Page 6: ...shall be made in accordance with applicable standards and regulations The PSU is designed for 10Mbit s and 100Mbit s Ethernet network so called Fast Ethernet However it can not be used for a 1000 Mbi...

Page 7: ...red battery output 0V BAT cable black 9 Check the optical indication of the PSU status green LED light on the PoE module 10 Close the cover after installing and checking the operation of the power su...

Page 8: ...ly Fig 6 Electrical diagram of the relay output CAUTION The arrangement of contacts at the figure 6 shows a potential free status of the relay which is equivalent to a state with no voltage at any of...

Page 9: ...ration the battery will be disconnected 4 3 Maintenance All maintenance procedures can be performed after disconnecting the power supply from the power network The PSU does not require any specific ma...

Page 10: ...service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...

Reviews: