CS10.241, CS10.241-S1
CS-Series
24V,
10A,
240W
S
INGLE
P
HASE
I
NPUT
Aug. 2022 / Rev. 2.1 DS-CS10.241-EN
All parameters are specified at 24V, 10A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
9/27
7.
H
OLD
-
UP
T
IME
AC 100V
AC 120V
AC 230V
Hold-up Time
typ.
62ms
107ms
103ms
at 24V, 5A, see Fig. 7-1
min.
50ms
86ms
83ms
at 24V, 5A, see Fig. 7-1
typ.
23ms
46ms
47ms
at 24V, 10A, see Fig. 7-1
min.
19ms
37ms
38ms
at 24V, 10A, see Fig. 7-1
typ.
17ms
35ms
37ms
at 24V, 12A, see Fig. 7-1
min.
14ms
28ms
30ms
at 24V, 12A, see Fig. 7-1
Fig. 7-1
Hold-up time vs. input voltage
Fig. 7-2
Shut-down behavior, definitions
0
20
40
120ms
85
120
100
180
230Vac
Hold-up Time
80
60
100
Input Voltage
a) 24V 5A typ.
b) 24V 5A min.
c) 24V 10A typ.
d) 24V 10A min.
e) 24V 12A min.
a
a
b
c
c
d
d
e
e
b
- 5%
Hold-up Time
Zero Transition
Output
Voltage
Input
Voltage
Note:
At no load, the hold-up time can be up to several seconds. The green DC-OK LED is on during this time.