Page 30
Operation
TM-1020 Series Progressive Scan Shutter Cameras
Model: TM-1020
Operation Mode: 15 Frames/Second
Master Clock: 40 MHz, M= 25 nsec
Pixel Clock: 20 MHz, P = 50 nsec
3. External Reset Timing
4. Async Reset Timing
External VD
Internal VD
FDV
Digital Data
Analog Video
VINIT Trigger
Internal VD
FDV
Digital Data
Analog Video
Horizontal Frequency: 15.748 KHz
1H = 63.50
µ
sec
A [1050 H], (66.68 msec)
B [0 H], (470.0 ns)
C [9 H], (572.0
µ
s)
D [1041 H], (66.10 ms)
E [ 1050 H], (66.68 ms)
F [0 H], (36 ns)
I [0 H], (260.0 ns)
L [0 H], (100 ns)
P [3 H], (190.5
µ
s)
G [32 H], (2.030 ms)
J [32 H], (2.040 ms)
M [29 H], (1.880 ms)
N [3 H], (190.5
µ
s)
H [1018 H], (64.64 ms)
K [1018 H], (64.64 ms)
O [1018 H], (64.64 ms)
S [1041 H], (66.10 ms)
T [ 1050 H], (66.68 ms)
Y [1018 H], (64.64 ms)
CC [1018 H], (64.64 ms)
Q [1 H], (68.00
µ
s)
U [0 H], (32.00 ns)
AA [29 H], (1.880 ms)
X [32 H], (2.040 ms)
BB [3 H], (190.5
µ
s)
DD [3 H], (190.5
µ
s)
W [9 H], (568.0
µ
s)
Z [0 H], (5
µ
s)
R [9 H], (572.0
µ
s)
V [32 H], (2.040 ms)