Page 25
GigE Series Camera Serial Commands
TM-1405GE Software
Note:
If a command is not accepted for any reason, the camera returns a Nack response “:e”<cr>
Report Command:
RPST<cr>
TS Return
: O RR + “24 bytes” + <cr>
Lookup Table
:LINR
<cr>
:o<cr>
Set linear table
:GM45
<cr>
:o<cr>
Set gamma .45 table
:KNEE=
X1Y1X2Y2
<cr>
:o<cr>
Set knees (X1, Y1, X2, Y2 = 00 - FF)
:NLUT
X
<cr>
:o<cr>
Set positive knee or negative knee
(X=0 positive, X=1 negative)
EEPROM
:WRPG
X
<cr>
:o<cr>
Write Page X = 0 - 6; (Page 0 is factory
setting, Page 1 is power up default set-
ting)
:LDPG
X
<cr>
:o<cr>
Load Page (X = 0 - 6)
:RDPG
X
<cr>
:o[set-
tings]<cr>
Read Page (X = 0 - 6)
:RPST
<cr>
:o[set-
tings]<cr>
Report current settings
Scan Mode
:SMDA
<cr>
:o<cr>
Set Full Scan Mode
:SMDU=
XXXXYYYY
<cr>
:o<cr>
Set User Scan Area (XXXXX=0000 -
040F, YYYY=0001 - 0410
Miscellaneous
:DDP
X
<cr>
:o<cr>
Set output data depth (X=0 8bit, X=1
10bit)
:TAH=
X
<cr>
:o<cr>
External Trigger Polarity (X=1 Active
High, X=0 Active Low)
:TPTN
X
<cr>
:o<cr>
Enable/Disable Test Pattern (X =
1Enable,
X = 0 Disable)
:CAM?
<cr>
:o[model]<
cr>
Enquire Camera Model
:VER?
<cr>
:o[ver-
sion]<cr>
Enquire MPU firmware version
Table 4.
TM-1405GE Command List (Continued)
Command
Parameters
End of
Command
Ack
Response
Description