![Pullman Holt 30ASB Operation & Care Instructions Download Page 2](http://html1.mh-extra.com/html/pullman-holt/30asb/30asb_operation-and-care-instructions_1623981002.webp)
ABOUT THE VACUUM
DISPOSABLE BAG CHANGING:
The recommended bag replacement procedure is as follows:
1. Remove can cap from unit.
2. Tape a 6-mil poly bag over the can cap so that the paper bag is
completely enclosed.
3. Using the poly bag as a glove, disengage the paper bag from the
can cap’s vacuum inlet stem.
4. Seal the poly bag and dispose as prescribed by law.
5. Attach a new paper bag securely to the vacuum inlet and fold the
bottom of the bag lengthwise.
6. Replace the can cap and close the clamps.
7. Thoroughly vacuum the work area to recover any asbestos dust
which may have been dropped.
GASKET REPLACEMENT:
If the air seal gasket is cut or otherwise damaged resulting in an air
leakage, simply remove it from the filter flange and replace it with a
new gasket.
10702 N 46th Street • Tampa, FL 33617
(813)971-2223 • toll free (800) 237-7582
fax (813) 971-6090 • order entry fax (800) 833-8875
www.pullmanholtcorp. com
B700006 1/04
Symptom
Possible Cause(s)
Corrective Action
Loss of Suction
1) Obstruction in hose or wand
1)
Clear hose
2) Clogged air filter assembly
2)
Brush Moleskin filter, replace primary filter
3) Uneven gasket fit
3)
Reposition or replace gasket
4) Dented canister rim
4)
Replace canister
Motor Won’t Run
1) Blown fuse or tripped circuit
1)
Replace fuse or reset circuit
2) Defective cordset
2)
Replace cordset
TROUBLE SHOOTING GUIDE
WARNING
To effectively control asbestos dust emissions from
the vacuum cleaner, All filters must be in place at all
times. If any visible dust emissions are observed in
the vacuum exhaust air stream, stop operations
immediately. If this occurs, the HEPA filter has rup-
tured or must be replaced.
WARNING :
Always disconnect power cable from electrical outlet when working on this machine.