For Wet Operation:
With HEPA
fi
lter and water pick-up pan in place, securely
clamp motor head to the spacer. When the maximum water
level is reached the water pick-up pan’s safety valve (
fl
oat)
closes off suction, automatically preventing further liquid
intake.
NOTE: This will cause the motor to race. Turn off motor,
remove and empty drum. Thoroughly clean
fl
oat
assembly. Replace water pick-up adapter, HEPA
fi
lter and motor head, then clamp securely. The
vacuum cleaner is ready for wet use.
*Can be purchased separately
For Dry Operation:
With the HEPA
fi
lter and motor head in place, secure the
hose end over the inlet. Wands and/or tools are then
fi
tted
to the opposite end of the hose. The vacuum cleaner is
ready for dry use.
Model 102ASB-DA
CAUTION
When removing the motor head, care in handling is essential.
Dropping, banging or other abuse may result in poor vacuum seal
and a loss in suction power and will invalidate your warranty.
102 Head
HEPA Filter
Spacer
Wet Pan
Drum Adapter
Gasket
55 Gallon Drum
*not included
102 Head
HEPA Filter
Drum Adapter
Gasket
55 Gallon Drum
*not included
Dolly
*not included
Dolly
*not included