Page 1: ...www u r x o b v a MUH44TPR2 N 4K HDBaseT 4x4 Matrix Switcher All Rights Reserved Version MUH44TPR2 N_2016V1 1 User Manual...

Page 2: ...roperties of the trademark owner No part of this publication may be copied or reproduced without the prior written consent of PTN Electronics Limited FCC Statement This equipment generates uses and ca...

Page 3: ...unit to rain moisture or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing...

Page 4: ...TPHD402PR 7 4 System Operations 8 4 1 Front Panel Button Control 8 4 1 1 Switching I O connection 8 4 1 2 EDID Management 8 4 1 3 Inquiry 10 4 1 4 Clear operation 11 4 2 IR Control 11 4 2 1 Usage of I...

Page 5: ...mited u r x o b v a w w w 4 4 TCP IP Control 23 4 4 1 Control Modes 23 4 4 2 GUI for TCP IP control 25 4 4 3 GUI Update 27 4 5 Firmware Update via USB 28 5 Specification 29 6 Panel Drawing 30 7 Troubl...

Page 6: ...nd Selected audio is output via HDMI outputs HDBaseT outputs and the audio output sockets The unit also supports bi directional RS232 IR control 1 2 Features Support HDMI 1 4 HDCP2 2 and compliant wit...

Page 7: ...4TPR2 N 2 x Mounting ears 6 x Screws 1 x RS232 cable 1 x IR Receiver 4 x Plastic cushions 4 x Black Screws 1 x IR remote 1 x Power Adapter DC 24V 2 71A 8 x Pluggable Terminal Blocks 1 x User manual No...

Page 8: ...ptions OUTPUTS buttons EDID Manageme nt buttons Normal mode Back lit buttons ranging from 1 to 4 Output 1 2 support synchronous local HDMI output EDID Invoking mode press and hold EDID button for 3 se...

Page 9: ...on the HDBaseT receivers and all IR signals can be switched synchronously with the AV signal or separately switched OUTPUTS a IR IN Connect with IR receiver fixed IR input for the output cannot be sw...

Page 10: ...with extended IR receiver use the IR remote to control MUH44TPR2 N TCP IP TCP IP port for unit control RS232 Serial port for unit control 9 pin female connector connects with control device such as a...

Page 11: ...arge screen displaying conference system television education and bank securities institutions etc 3 2 Usage Precautions 1 System should be installed in a clean environment and has a prop temperature...

Page 12: ...the included IR remote via its built in IR sensor or through external IR receiver connected to the IR IN IR EYE IR ALL IN port The IR signal can be transmitted bi directionally between MUH44TPR2 N an...

Page 13: ...t an HDMI input to an output the corresponding IR OUT will be switched synchronously 2 To convert an input to several outputs Operation input output output ENTER Example Switch input 2 to output 2 4 3...

Page 14: ...ff immediately EDID invoking There are five types of embedded EDID data The chart below illustrates the detailed information of the embedded EDID data No EDID Data 1 1080P 2D 2CH 2 1080P 3D 2CH 3 1080...

Page 15: ...items Function Items Example Description Check the connection status of inputs Y means the corresponding port is connected with input device N means not Check the connection status of outputs Y means...

Page 16: ...m local 2 Control local input output device remotely 3 Control the MUH44TPR2 N locally remotely 4 2 1 Usage of IR Remote Standby button press it to enter exit standby mode Input channels range from 1...

Page 17: ...ol Far end Device locally Connect an IR receiver to IR IN IR ALL IN on the switcher and use the IR Remote of far end device to control the device locally 1 to 1 through IR IN Connect an IR receiver wi...

Page 18: ...end HDBT receiver s and IR Emitter s to IR OUT port of the switcher and use the IR Remote of local source to control the device remotely 1 to 1 Connect an IR receiver to IR IN on far end HDBT receiver...

Page 19: ...ommand reference to 4 3 RS232 Control x1 R x2 x1 Corresponding to the 4 IR OUT ports of the matrix the IR transmitter connected to this port can be placed at IR receiving area of output device or MUH4...

Page 20: ...control the switcher far end device See the figure below PC PoC 3rd party TPHD402PR Control the switcher 3rd party Device through 9 pin female RS232 port Control the switcher send RS232 commands dire...

Page 21: ...d device receiver see below PC PoC 3rd party TPHD402PR Control 3rd party device from remote 4 3 4 Installation uninstallation of RS232 Control Software Installation Copy the control software file to t...

Page 22: ...d Sending Area 4 3 6 RS232 Communication Commands Note 1 Please disconnect all the twisted pairs before sending command EDIDUpgrade X 2 In above commands and are symbols for easy reading and do not ne...

Page 23: ...1 01 AV 01 02 IR 01 02 AV 04 04 IR 04 04 Undo To cancel the previous operation Undo Ok Out 01 02 03 04 In 01 01 01 01 Operation Commands x All Transfer signals from the input channel x to all output c...

Page 24: ...Recall the preset command Y Recall From FY Y 0 9 Clear Y Clear the preset command Y Clear FY Y 0 9 PWON Work in normal mode PWON PWOFF Enter into standby mode and cut off the power supply to HDBaseT...

Page 25: ...trol all far end devices c Y A B C or D d Y E F G or H For items c or d send this command it will be saved to the matrix switcher but taken without action to corresponding HDBaseT receiver And its com...

Page 26: ...D data via the RS232 port x is the input port when the value of X is 9 it means to upgrade all input ports When the switcher receives the command it will show a message to prompt you to send EDID file...

Page 27: ...he command sent by port 4 when PWON Port 4 data when PWON 9955 Check the command sent by port 1 when PWOFF Port 1 data when PWOFF 9956 Check the command sent by port 2 when PWOFF Port 2 data when PWOF...

Page 28: ...Y Y Y Y 4 4 TCP IP Control MUH44TPR2 N boasts option TCP IP port for IP control Default settings IP 192 168 0 178 Subnet Mast 255 255 255 0 Gateway 192 168 0 1 Serial Port 4001 IP gateway can be chan...

Page 29: ...router s then PCs within the LAN are able to control MUH44TPR2 N Router Internet PC TCP IP Port Follow these steps to connect the devices Step1 Connect the TCP IP port of the MUH44TPR2 N to Ethernet p...

Page 30: ...llows users to interact with MUH44TPR2 N through graphical icons and visual indicators Type 192 168 0 178 in your browser it will enter the log in interface shown as below There are 2 selectable usern...

Page 31: ...ving and recall for overall connection status Users Display or modify credential settings front panel lock and GUI version If there is any modification press Save to restore the settings or press Canc...

Page 32: ...ote Log in as user access main interface only 4 4 3 GUI Update GUI for MUH44TPR2 N supports online update in http 192 168 0 178 100 Type the username and password the same as the GUI log in settings m...

Page 33: ...ow these steps to upgrade firmware Step1 Copy the upgrade software and the latest upgrade file bin to PC Step2 Connect the USB ports of MUH44TPR2 N and the PC via USB cable Step3 Double click the upda...

Page 34: ...Switching Speed 200ns Max EDID Management In built EDID data and manual EDID management HDCP Supports HDCP 2 2 auto and manual HDCP management Audio General Output Signal Stereo audio Digital audio Ou...

Page 35: ...cher PTN Electronics Limited 3 u r x o b v a w w w 0 General Power Supply DC 24V 2 71A Power Consumption 48W Max Temperature 10 40 Reference Humidity 10 90 Dimension W H D 437 x 44 x 235 mm 1U high fu...

Page 36: ...S MENU ENTER IR FIRMWARE SYSTEM MONITOR 436 40 mm 23 10 mm 44 00 mm 31 80 mm RS232 IR EYE TCP IP HDMI INPUTS IR OUT 1 2 3 4 1 2 3 4 OUTPUTS HDMI AUDIO HDBaseT HDMI 2 3 4 L R AUDIO L R AUDIO L R AUDIO...

Page 37: ...and Y X 1 or change HDCP compliance status in GUI The display doesn t support the input resolution Switch for another input source or enable the display to learn the EDID data of the input Cannot cont...

Page 38: ...e g a PC through RS232 port Wrong connection Check to ensure the connection between the control device and the unit Wrong RS232 communication parameters Type in correct RS232 communication parameters...

Page 39: ...removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warranty...

Page 40: ...www u r x o b v a PTN Electronics Limited Tel 3 8 8 1 3 3 3 4 0 8 8 Email u r x o b v a i Website u r x o b v a p t t h...