10356360_V_1_1.DOC
24/32
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
STARTING UP
Make sure to power-up before your power amplifier is turned in order to avoid loud transients which could
damage your speakers or annoy your audience.
System test
After connecting all cables, you should carry out a system test. Press all Mute-buttons in order to mute all
outputs.
Activate the HF-outputs first. In case of wrong cabling, HF-signals will come out of bass-speakers that cannot
be harmed this way. Vice versa, the LF-signals would destroy your HF-speakers.
OPERATION
Switch the device on via the power-switch.
The following initialization screen will show up on the LCD:
The initialization process will take about 8 seconds.
After successful initialization the display shows the current program number and program name. The current
program is always the last program the used has recalled or stored before powering down the unit.