background image

LD160  REV.E1-1 

PSM LD16x vehicle loop detector installation guide 

1.

 

Pin connections 

 

MODEL NO. 

 

PIN 

161 

162 

163 

 

110 VAC, LINE 

230 VAV, LINE 

12~24 VADC 

LD-161 

110 VAC, NEUTRAL 

230 VAC, NEUTRAL  12~24 VADC 

 

Output B Relay (N.O.) 

Output B Relay (N.O.) 

 

Chassis Ground 

Output B Relay (COM.) 

 

Output A Relay (COM.)  Output A Relay (COM.) 

 

Output A Relay (N.O.) 

Output A Relay (N.O.) 

 

Loop 

Loop 

LD-162 

Loop 

Loop 

LD-163 

Output B Relay (COM.)  Chassis Ground 

 

10  Output A Relay (N.C.) 

Output A Relay (N.C.) 

 

11  Output B Relay (N.C.) 

Output B Relay (N.C.) 

 

 

2.

 

Front panel LED and switch 

(1) POWER

POWER RED LED

On= Power applied to detector.

Off = No power or fuse is 

bad. 

(2) DETECT

DETECT GREEN LED

On = Vehicle being detected

Blinking = Loop Failure. 

(3) SWITCH 1(SENSITIVITY)

Selections of sensitivity are from 0 to 9 and A to F where 0 

stands for the lowest sensitive and F is the highest sensitive. 

                        Unit

-

ΔL/L × 100

 

SENSITIVITY LEVELS 

LEVEL 0 

2.56 

LEVEL 4 

0.48 

LEVEL 8 

0.12 

LEVEL C 

0.030 

LEVEL 1 

1.28 

LEVEL 5 

0.32 

LEVEL 9 

0.08 

LEVEL D 

0.020 

LEVEL 2 

0.96 

LEVEL 6 

0.24 

LEVEL A 

0.06 

LEVEL E 

0.015 

LEVEL 3 

0.64 

LEVEL 7 

0.16 

LEVEL B 

0.04 

LEVEL F 

0.010 

(4) SWITCH 2(DIP SWITCH)

 

1. 

DIP 1 & DIP 2    FUNCTION

 

DIP NO. 

DIP MODE 

FUNCTION 

DIP 1 

□■

ON 

2 seconds delay for the relay.    It will be no output for a vehicle with a speed 

that is faster than 8 Km/Hr. 

DIP 2 

□■

ON 

Increase detector’s sensitivity to avoid the failed detection. Especially in the 

case of trailer or trucks.     

2. 

DIP 3 & DIP 4 

  OUTPUT B MODE

 

DIP NO. 

DIP 3 

DIP 4 

OUTPUT B MODE 

DETECT

         

 

DIP MODE 

OFF

■□

 

OFF

■□

 

Pulse on entry 

Output  B  mode   

 

 

□■

ON 

OFF

■□

 

Pulse on exit 

Output  B  mode     

 

OFF

■□

 

□■

ON  Presence mode 

Output  B  mode

     

 

□■

ON 

□■

ON  Output B will set to the presence mode when the loop failed. 

3. 

DIP 5 FUNCTION

 

DIP NO. 

DIP 5 

PRESENCE MODE 

DIP MODE 

□■

ON 

Continuous detect output is maintained as long as the vehicle remains on 

the loop. 

OFF

■□

 

Hold time of 5 minutes for any vehicle detected. 