Psion PowerScan M8300 series Quick Reference Manual Download Page 5

Technical Support

For technical support in North America:

Call Toll free: +1 800 387 8898 Option 3, 

or

 

Direct Dial:

+1 905 813 9900 Ext. 1999 Option 3.

For technical support outside of North America, please follow the link 
for your region on the Psion Community Support website at:

http://community.psion.com/support

Product Repairs

For repair service in North America:

Call Toll free: +1 800 387 8898  Option 2, 

or

 

Direct Dial:

+1 905 813 9900 Ext. 1999  Option 2.

For repair service outside of North America, please 
contact your local office listed in the following document:

http://www.psion.com/documents/com/quickReferenceGuides/

Help_Desk_Contact_Numbers_A4.pdf

Worldwide Offices

Company Headquarters

Psion Inc.

2100 Meadowvale Boulevard
Mississauga, Ontario, Canada L5N 7J9
Tel:

+1 905 813 9900

Fax:

+1 905 812 6300

E-mail: [email protected]

North American Headquarters & U.S. Service Centre

Psion Corporation

3000 Kustom Drive
Hebron, Kentucky
USA 41048
Tel:

+1 859 371 6006

Fax:

+1 859 371 6422

E-mail: [email protected]

International Subsidiaries

www.psion.com/us/about/contact_psion-offices.htm

Psion S.A.

Psion Espana S.L.

La Duranne

Plaza de la Pau, s/n Edificio 3, 2º 

135 Rue Rene Descartes

08940 Cornella de Llobregat,

BP 421000

Barcelona, Spain

13591 Aix-En-Provence
Cedex 3; France
Tel:

+33 4 42 90 88 09

+34 902 884 220

Fax:

+33 4 42 90 88 88

+34 934 750 230

E-mail: [email protected]

[email protected]

Summary of Contents for PowerScan M8300 series

Page 1: ...PowerScan M8300 READERS QUICK REFERENCE GUIDE August 16 2011 PN 8000169 B ISO 9001 Certified Quality Management System...

Page 2: ...whole or in part except for the sole purpose of assisting in proper use of Psion manufactured goods and services by their rightful own ers and users Any other use of this document is prohibited Discl...

Page 3: ...n updates for this product are available on the Internet Log on to www psion com I Su Internet sono disponibili le versioni aggiornate di driver e docu mentazione di questo prodotto Questo manuale dis...

Page 4: ...the maximum trace levels of lead cadmium mercury hexavalent chromium and flame retardants PBB and PBDE that may be contained in a product Only products meeting these high environmental standards may b...

Page 5: ...com quickReferenceGuides Help_Desk_Contact_Numbers_A4 pdf Worldwide Offices Company Headquarters Psion Inc 2100 Meadowvale Boulevard Mississauga Ontario Canada L5N 7J9 Tel 1 905 813 9900 Fax 1 905 81...

Page 6: ...NOTES...

Page 7: ...0 laser readers automatically scan barcodes at a distance Simply aim and pull the trigger Scan Line Position Code scanning is performed along the scan line emitted from the reading window This line mu...

Page 8: ...ch should be aimed over the code center to get the best reading performance see figure 1 above By completely pressing the trigger the scan line appears to start the code scanning 2 After setting up th...

Page 9: ...or the C 8000 battery charger The Reader LED on the cradle battery charger turns red The battery is completely charged when the Reader LED on the cradle battery charger turns green To change the batte...

Page 10: ...e BC 80X0 Configuration in the BC 80X0 Quick Reference or PowerScan M8300 BC 80X0 Stand Alone Configuration 1 Connect a BC 80X0 cradle to the Host For installation and connection information see the B...

Page 11: ...rapidly configure your point to point application END OF PROCEDURE YOUR READER IS NOW READY TO READ CODES 1 Apply the bind address label onto the BC 80X0 base station as indicated in the BC 80X0 Crad...

Page 12: ...eric code selection of steps 3 4 and 5 use the table at the end of this Quick Reference Guide 1 Restore PowerScan M8300 Default o 2 Enter Configuration 3 Set Date IA six digits for Day Month and Year...

Page 13: ...ers to the same cradle see the following section Using Multiple Readers with Same Cradle Bind RN0 I The green LED on the PowerScan M8300 will blink the reader is ready to be positioned onto the cradle...

Page 14: ...TAR MODEM Stand Alone Setup To configure a PowerScan M8300 reader to communicate with STAR Modem in Stand Alone Mode follow the PowerScan M8300 BC 80X0 Stand Alone Setup procedure substituting steps 6...

Page 15: ...System devices such as Stargate RF base stations 1 Restore PowerScan M8300 Default o 2 Enter Configuration 3 Set Date IA six digits for Day Month and Year DDMMYY 4 Set Time IB four digits for Hours a...

Page 16: ...the same area must have different addresses 7 Set First STAR System Address RSR four digits from the Numeric Table in the range 0000 to 1999 8 Set Last STAR System Address RTT four digits from the Num...

Page 17: ...characters Standard Code 39 no check digit control variable length code 1 99 characters Code 128 variable length code 1 99 characters disabled codes EAN 128 ISBT128 Code 93 Codabar pharmaceutical cod...

Page 18: ...solution 0 076 mm 3 mils 0 19 mm 7 5 mils PCS minimum Datalogic Test Chart 15 25 Scan Angle 42 13 5 0 7 Laser Safety Class 2 EN 60825 1 CDRH Radio Features European Models USA Models Radio Frequency 4...

Page 19: ...5 24 2 cm 1 4 9 5 in 10 2 9 42 8 cm 1 1 16 8 in 13 2 3 55 1 cm 0 9 21 7 in 20 6 3 78 5 cm 2 5 30 9 in 40 2 5 97 8 cm 1 0 38 5 in mil Typical reading distance with good quality codes 7 5 18 50 cm 7 0...

Page 20: ...PSION 14 PowerScan M8300 Numeric Table 01 0 12 1 23 2 34 3 45 4 56 5 67 6 78 7 89 8 9 9...

Page 21: ...Numeric Table Quick Reference Guide 15 NOTES...

Page 22: ...is based upon compliance of the products to the following standards Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf da das Produkt den folge...

Reviews: