PSG Wilden PS220 Series Engineering, Operation & Maintenance Download Page 27

W A R R A N T Y

Each and every product manufactured by Wilden Pump and Engineering, LLC is built to meet the highest 
standards of quality. Every pump is functionally tested to insure integrity of operation.
Wilden Pump and Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by 
it to be free from defects in material and workmanship for a period of five (5) years from date of installation or 
six (6) years from date of manufacture, whichever comes first. Failure due to normal wear, misapplication, or 
abuse is, of course, excluded from this warranty.
Since the use of Wilden pumps and parts is beyond our control, we cannot guarantee the suitability of any pump 
or part for a particular application and Wilden Pump and Engineering, LLC shall not be liable for any consequential 
damage or expense arising from the use or misuse of its products on any application.  Responsibility is limited 
solely to replacement or repair of defective Wilden pumps and parts.
All decisions as to the cause of failure are the sole determination of Wilden Pump and Engineering, LLC.
Prior approval must be obtained from Wilden for return of any items for warranty consideration and must be 
accompanied by the appropriate MSDS for the product(s) involved. A Return Goods Tag, obtained from an 
authorized Wilden distributor, must be included with the items which must be shipped freight prepaid.
The foregoing warranty is exclusive and in lieu of all other warranties expressed or implied (whether written or oral) 
including all implied warranties of merchantability and fitness for any particular purpose. No distributor or other 
person is authorized to assume any liability or obligation for Wilden Pump and Engineering, LLC other than expressly 
provided herein.

Item # 

Serial # 

Company Where Purchased

Company Name

Industry

Name Title

Street Address

City 

State 

Postal Code 

Country 

Telephone 

Fax 

E-mail 

Web Address 

Number of pumps in facility? 

Number of Wilden pumps?

Types of pumps in facility (check all that apply): 

 Diaphragm  

 Centrifugal 

 Gear 

 Submersible 

 Lobe

 

 Other  

Media being pumped? 

How did you hear of Wilden Pump? 

 Trade Journal 

 Trade Show 

 Internet/E-mail 

 Distributor 

 

 Other 

PLEASE PRINT OR TYPE AND FAX TO WILDEN

P U M P   I N F O R M AT I O N

YO U R   I N F O R M AT I O N

ONCE COMPLETE, FAX TO (909) 783-3440

OR GO TO PSGDOVER.COM > WILDEN > SUPPORT TO COMPLETE THE WARRANTY REGISTRATION ONLINE

NOTE: WARRANTY VOID IF PAGE IS NOT FAXED TO WILDEN OR SUBMITTED ONLINE VIA THE PSGDOVER.COM WEBSITE

WILDEN PUMP & ENGINEERING, LLC

Summary of Contents for Wilden PS220 Series

Page 1: ...EOM Engineering Operation Maintenance wildenpump com Where Innovation Flows PS220 PS230 FIT Metal Pump...

Page 2: ...5 PERFORMANCE PS220 PS230 Rubber Fitted 6 PS220 PS230TPE Fitted 6 PS220 PS230 Full Stroke PTFE Fitted 7 SECTION 6 SUGGESTED INSTALLATION OPERATION TROUBLESHOOTING 9 SECTION 7 DISASSEMBLY REASSEMBLY 12...

Page 3: ...flammable fluids and whenever discharge of static electricity is a hazard CAUTION Do not exceed 8 6 bar 125 psig air supply pressure CAUTION The process fluid and cleaning fluids must be chemically co...

Page 4: ...TE NOT ALL PUMP MODELS ARE AVAILABLE WITH ALL MATERIAL OPTIONS 0493 U L Approved Center Ported NPT Turbo drop in 1 Inlet facing air inlet 3 4 discharge facing exhaust 0494 U L Approved Center Ported N...

Page 5: ...nd manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump di...

Page 6: ...inch A 361 14 2 B 36 1 4 C 163 6 4 D 254 10 0 E 287 11 3 F 56 2 2 G 417 16 4 H 71 2 8 J 140 5 5 K 155 6 1 L 206 8 1 M 173 6 8 N 104 4 1 P 127 5 0 R 10 0 4 LW0364 REV A DIMENSIONS ITEM METRIC mm STAND...

Page 7: ...NDARD inch A 373 14 7 B 69 2 7 C 195 7 6 D 287 11 3 E 340 13 4 F 343 13 5 G 71 2 8 H 417 16 4 J 71 2 8 K 140 5 5 L 188 7 4 M 206 8 1 N 173 6 8 P 104 4 1 R 127 5 0 S 10 0 4 T 203 8 0 DIN mm ANSI inch U...

Page 8: ...and performance pumps should be specified so that daily operation parameters will fall in the center of the pump s performance curve Flow rates indicated on chart were determined by pumping water For...

Page 9: ...le Iron 29 kg 64 lb 316 Stainless Steel 31 kg 68 lb Air Inlet 13 mm 1 2 Inlet 25 mm 1 Outlet 25 mm 1 Suction Lift 5 2 m Dry 17 0 9 0 m Wet 29 5 Disp Per Stroke1 0 30 L 0 08 gal Max Flow Rate 197 lpm 5...

Page 10: ...ng at 305 m 1 000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscos...

Page 11: ...lers can be used to further reduce sound levels but they usually reduce pump performance ELEVATION Selecting a site that is well within the pump s dynamic lift capability will assure that loss of prim...

Page 12: ...to the pump therefore stopping output This shut off valve should be located far enough away from the pumping equipment such that it can be reached safely in an emergency situation NEEDLE VALVE AIR SH...

Page 13: ...ake it possible to identify pumps that are poorly suited to their applications Pump will not run or runs slowly 1 Ensure that the air inlet pressure is at least 0 3 bar 5 psig above startup pressure a...

Page 14: ...ing it upside down and allowing any fluid to flow into a suitable container Be aware of any hazardous effects of contact with your process fluid NOTE The model photographed is a metal PX200 25 mm 1 pu...

Page 15: ...manifold Step 6 Remove the inlet valve balls seats and valve seat O rings from the liquid chamber and inlet manifold inspect for nicks gouges chemical attack or abrasive wear Step 7 Using a 13 mm 1 2...

Page 16: ...cure shaft with soft jaws a vise fitted with plywoodorothersuitablematerial to ensure shaft is not nicked scratched or gouged Using an adjustable wrench removediaphragmassembly from shaft Inspect all...

Page 17: ...ects of contact with your process fluid The Wilden Pro Flo SHIFT metal pumps utilize a revolutionary Pro Flo SHIFT air distribution system Proprietary composite seals reduce the coefficient of frictio...

Page 18: ...y Step 6 Remove pilot spool sleeve retaining snap ring on both sides of center section with snap ring pliers Step 7 Remove pilot spool sleeve from center section Step 8 With O ring pick gently remove...

Page 19: ...tep 2 Next install an optional single point exhaust gasket 02 2621 52 The single point air valve gasket can be purchased as a spare part or included with the purchase of a new Pro Flo SHIFT pump Step...

Page 20: ...surface of the new seal With a new seal in hand place the two legs of the needle nose pliers inside the seal ring See Figure A Open the pliers as wide as the seal diameter will allow then with two fi...

Page 21: ...N O T E S...

Page 22: ...P L O D E D V I E W P A R T S L I S T I N G PS220 PS230 METAL E X P L O D E D V I E W WILDEN PUMP ENGINEERING LLC 20 WIL 11560 E 07 FULL STROKE PTFE FULL STROKE IPD STAINLESS STEEL FLANGED ALL CIRCLE...

Page 23: ...5090 01 02 5090 02 02 5090 03 Inlet Manifold DIN Flange 1 02 5091 01 02 5091 02 02 5091 03 18 Discharge Manifold Side Ported 1 NPT 1 02 5035 01 02 5035 02 02 5035 03 Discharge Manifold Side Ported 1...

Page 24: ...N 02 1010 86 N A N A N A N A N A N A N A FKM 02 1010 53 N A N A N A 02 1085 53 N A 02 1205 53 02 1372 53 EPDM 02 1010 54 N A N A N A 02 1085 54 N A 02 1205 54 02 1372 54 PTFE N A 02 1040 55 N A N A 0...

Page 25: ...N O T E S...

Page 26: ...N O T E S...

Page 27: ...s for warranty consideration and must be accompanied by the appropriate MSDS for the product s involved A Return Goods Tag obtained from an authorized Wilden distributor must be included with the item...

Page 28: ...nt without prior notice This is a non contractual document 11 2018 Authorized PSG Representative Copyright 2018 PSG ADoverCompany WIL 11560 E 07 REPLACES WIL 11560 E 07 PSG 22069 Van Buren St Grand Te...

Reviews: