NT 1002-C00 11.11 S6C S6C HP Pumps e
9/12
5. ASSEMBLY / DISMANTLING
5.1 Necessary tools
- Wrench no. 13
- Wrench no. 16
- Wrench no. 19
- Plastic mallet
- Hexagonal socket wrench no. 6
Assembly torques :
- M8 : 23,7 Nm
- M10 : 30 Nm
- M12 : 50 Nm
Before any dismantling, make sure that the
pump has been drained and take all necessa-
ry measures to avoid its start-up.
No start-up, even accidental, must be possible.
TAKE ALL NECESSARY MEASURES TO
RENDER ANY START-UP, EVEN ACCIDEN-
TAL, OF THE PUMP DURING THE WORK
IMPOSSIBLE.
WARNING
Any unforeseen start-up
can cause serious
injuries or important
material damages.
FAILURE TO RELIEVE SYSTEM PRESSU-
RE PRIOR TO PERFORMING PUMP SERVI-
CE OR MAINTENANCE CAN CAUSE PER-
SONAL INJURY OR PROPERTY DAMAGE.
CAUTION
Hazardous pressure
can cause
personal injury
or property damage.
BE CAREFUL WITH THE WEIGHT OF
THE PARTS WHEN THEY ARE BEING
REMOVED.
WARNING
The weight ot the parts can
be dangerous and may
provoke bodily injuries or
material damages.
DISCONNECTING THE FLUID OR PRESSU-
RE CONTAINMENT COMPONENTS
DURING PUMP OPERATION CAN CAUSE
SERIOUS PERSONAL INJURY, DEATH OR
MAJOR PROPERTY DAMAGE.
WARNING
Hazardous pressure
can cause
personal injury
or property damage.
IF PUMPING HAZARDOUS OR TOXIC
FLUIDS, THE SYSTEM MUST BE FLUSHED
PRIOR TO PERFORMING ANY SERVICE
OPERATION.
WARNING
Hazardous or toxic
fluids can cause
serious injury.
THE PUMP LUBRICANT IS VERY SLIPPERY
AND MAY CAUSE SERIOUS INJURY. ANY
SPILLS MUST BE CLEANED UP.
CAUTION
Slippery lubricant.
Spills should be
cleaned up.