Suggested Installation, Operation, Maintenance and Troubleshooting

 

 

 

 

This illustration is a generic 
representation of an air-operated 
double-diaphragm pump.

 

 
 

 

 

 

 

 
 
 

 

 

 

 

 

 

 

 

 
 
 

 

 

 

 

 

 

NOTE: 

In the event of a power failure, the shut-off 

valve should be closed, if the restarting of the pump is 
not desirable once power is regained. 

Air-Operated Pumps: 

To stop the pump from operating in an 

emergency situation, simply close the shut-off valve (user-
supplied) installed in the air supply line. A properly functioning 
valve will stop the air supply to the pump, therefore stopping 

output. This shut-off valve should be located far enough away  
from the pumping equipment such that it can be reached safely  
in an emergency situation 

Operation 

The P.025 is permanently lubricated, and does not require in-
line lubrication. Additional lubrication will not damage the pump; 
however, if the pump is heavily lubricated by an external source, 

the pump’s internal lubrication may be washed away. If the 

pump is then moved to a non-lubricated location, it may need to 
be disassembled and re-lubricated as described in the 

DISASSEMBLY/REASSEMBLY INSTRUCTIONS. 
Pump discharge rate can be controlled by limiting the volume and/or 
pressure of the air supply to the pump. An air regulator is used to 
regulate air pressure. A needle valve is used to regulate volume. 

Pump discharge rate can also be controlled by throttling the pump  

discharge by partially closing a valve in the discharge line of the pump. This action 

increases friction loss which reduces flow rate. (See Section 5.) This is useful when 
the need exists to control the pump from a remote location. When the pump 
discharge pressure equals or exceeds the air supply pressure, the pump will stop; 

no bypass or pressure relief valve is needed, and pump damage will not occur. The 

pump has reached a “deadhead” situation

 and can be restarted by reducing the fluid 

discharge pressure or increasing the air inlet pressure. Wilden Pro-Flo

®

 pumps run 

solely on compressed air and do not generate heat; therefore, your process fluid 
temperature will not be affected. 

Maintenance and Inspections 

Since each application is unique, maintenance schedules may be different for 
every pump. Frequency of use, line pressure, viscosity and abrasiveness of 
process fluid all affect the parts life of a Wilden pump. Periodic inspections 
have been found to offer the best means for preventing unscheduled pump 

downtime. Personnel familiar with the pump’s construction and service should 

be informed of any abnormalities that are detected during operation. 
.

Summary of Contents for WILDEN PRO-FLO P.025

Page 1: ...EOM ENGINEERING OPERATION MAINTENANCE P 025 Clamped Plastic Pump WIL 10090 E 08 Where InnovationFlows...

Page 2: ...25 Plastic Rubber Fitted 8 P 025 Plastic TPE Fitted 8 P 025 Plastic PTFE Fitted 9 Suction Lift Curves 10 Section 6 Suggested Installation Operation 11 Maintenance and Troubleshooting Section 7 Disasse...

Page 3: ...ifornia LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are regist...

Page 4: ...ng pumped may be forced out air exhaust WARNING Prevent static sparking If static sparking occurs fire or explosion could result Pump valves and containers must be properly grounded when handling flam...

Page 5: ...UP O RING IPD White WFS WIL FLEX Santoprene Three Black Dots VALVE BALLS TF PTFE White VALVE SEATS K PVDF P POLYPROPYLENE MANIFOLD O RINGS BN BUNA N Red Dot TV PTFE ENCAP FKM WF WIL FLEX Santoprene P...

Page 6: ...ese same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of di...

Page 7: ...Wilden 7 P 025 Plastic DIMENSIONS ITEM METRIC mm STANDARD inch A 145 5 7 B 25 1 0 C 94 3 7 D 140 5 5 E 163 6 4 F 56 2 2 G 30 1 2 H 30 1 2 J 114 4 5 K 61 2 4 L 74 2 9 M 53 2 1 N 64 2 5 P 5 2 REV B DIME...

Page 8: ...ps should be specified so that daily operation parameters will fall in the center of the pump s performance curve P 025 PLASTIC TPE FITTED Est Ship Weight Polypropylene 1 4 kg 3 lb PVDF 1 4 kg 3 lb Ai...

Page 9: ...ke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 bar 30 psig head pressure Example To pump 8 7 lpm 2 3 gpm against a discharge pressure head of 2 bar 30 psig requires 4 1 bar 60 psi...

Page 10: ...ng at 1 000 305 m above sea level This chart is meant to be a guide only There are many variables which can affect your pump s operating characteristics The number of intake and discharge elbows visco...

Page 11: ...es should be used This valve allows trapped air between the valve and the pump to bleed off which improves pump performance Pumping volume can be estimated by counting the number of strokes per minute...

Page 12: ...ting the volume and or pressure of the air supply to the pump An air regulator is used to regulate air pressure A needle valve is used to regulate volume Pump discharge rate can also be controlled by...

Page 13: ...mbers 2 Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped cavitation 3 Verify that vacuum required to lift liquid is not greater than the v...

Page 14: ...tion consisting of center block and air chambers is molded from Acetal or polypropylene All fasteners and hardware are stainless steel The air valve is manufactured of Acetal or polypropylene All O ri...

Page 15: ...ball and seats for abrasion Inspect seat O rings and bottom retainer O rings for swelling cracking or other damage These parts should be replaced if damage is observed Step 7 Loosen clamp band with 5...

Page 16: ...move diaphragm and inner piston NOTE PTFE fitted pumps employ a PTFE diaphragm with an integral outer piston Turn diaphragm counterclockwise to loosen NOTE PTFE fitted pumps utilize a neoprene back up...

Page 17: ...3 mm 1 8 air inlet connects the air supply to the center section Proprietary composite seals reduce the coefficient of friction and allow the P 025 to run lube free Constructed of Acetal or polypropy...

Page 18: ...valve with NLGI grade 2 white EP bearing grease or equivalent Step 5 Remove the porous polyethylene muffler element by sliding it toward the end cap opening The element can be cleaned by soaking it i...

Page 19: ...fore the diaphragm assembly Concave side of disc spring in diaphragm assembly faces toward inner piston PRO FLO MAXIMUM TORQUE SPECIFICATIONS Description of Part Torque Air Valve 2 3 N m 20 in lbs Liq...

Page 20: ...WIL 10090 E 08 Wilden 20 Exploded View and Parts Listing P 025 PLASTIC RUBBER TPE FITTED EXPLODED VIEW Section 8...

Page 21: ...Ring 1 00 2650 03 700 00 2650 03 700 11 Shaft 1 00 3800 99 700 00 3800 99 700 12 Disc Spring 2 00 6800 08 00 6800 08 13 Inner Piston for Rubber TPE 2 00 3700 20 700 00 3700 20 700 14 Outer Piston 2 00...

Page 22: ...WIL 10090 E 08 Wilden 22 Exploded View and Parts Listing P 025 PLASTIC PTFE FITTED EXPLODED VIEW...

Page 23: ...ft 1 00 3800 99 700 00 3800 99 700 12 Disc Spring 2 00 6800 08 00 6800 08 13 Inner Piston for Rubber TPE 2 00 3700 20 700 00 3700 20 700 14 Outer Piston 2 00 4570 20 00 4570 21 15 Liquid Chamber 2 00...

Page 24: ...ee Section O Rings Wil Flex 00 1200 58 00 1260 58 00 1010 58 00 1070 58 00 1080 58 00 1300 58 Buna N 00 1200 52 00 1260 52 00 1010 52 00 1080 52 00 1300 52 FKM 00 1080 53 PTFE 00 1030 55 00 1080 55 St...

Page 25: ...WIL 10090 E 08 Wilden Notes...

Page 26: ...WIL 10090 E 08 Wilden Notes...

Page 27: ...WIL 10090 E 08 Wilden Notes...

Page 28: ...Terrace CA 92313 5651 USA P 1 909 422 1730 F 1 909 783 3440 psgdover com Where Innovation Flows PSG reserves the right to modifythe information and illustrations contained in this document without pr...

Reviews: