Code 93 Enable
Product Reference Guide
5-251
Code 93 Maximum Label Length
This feature specifies the maximum allowable length of a Code 93 label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET CODE 93 MAXIMUM LABEL LENGTH
below. You’ll need to cover any unused bar codes on this and the fac-
ing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C
that rep-
resent the desired maximum label length. The selectable range for
this option is 01 to 50. Pad all single digit numbers with a leading
zero to yield a two-digit entry (01-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET CODE 93 MAXIMUM LABEL LENGTH
NOTE
Length in this case includes data characters, but does not include
start, stop, full ASCII shift, or check characters. This feature applies
when
Code 93 Length Control
is set to variable-length decoding.
Maximum label length should be greater than or equal to minimum
label length.