The Prozone system works when air is drawn across a high-energy vacuum ultraviolet (VUV) lamp, converting some air to ozone. The 

ozone is introduced into the water either by direct injection or through a bypass venturi system. For direct injection, the venturi injector 

is inserted directly into the return line of the pool creating a suction (vacuum) that draws the ozone into the venturi as the water returns 

to the pool. The bypass venturi system takes water directly after the circulation pump (highest pressure point), bypasses part of the 

water flow past filters, heater, etc. through a venturi injector, through contact tubing and then returns the water back to the pool return 

line. A check valve is employed to prevent water backup in the event of system failure. The system should be run 6-8 hours per day for 

best effect. Run time may vary depending on usage.  

INSTALLATION KIT INVENTORY 

 

 

 

 

 

 

 

 

  

Note: For pools using a Diatomaceous Earth filter and Bypass / Venturi Injector installation, add (1) ¾” Ball Valve, (2) ¾” MPT x HB 

fittings, and (2) 1 ¼” metal clamps.  


TROUBLESHOOTING GUIDE

 

PROBLEM

 

PROBABLE CAUSE

 

REMEDY

 

Loose wiring 

Check all wiring connections 

No power to unit 

Check voltage compatibility 

Check power source 

No light from Prozone unit 

Defective lamp or other internal component 

Return unit to dealer 

Excessive back pressure 

Check for kinks or clogs in hose or plumbing 

Leak in fitting 

Replace fitting 

No bubbles from injector or 

no evidence of ozone in pool 

Filter not working 

Check filter 

Water in Ozone Generator 

Check Valve failure 

Verify Check Valve in Venturi is operating properly 

Water chemistry out of balance 

Check readings and balance accordingly 

Total Dissolved Solids (TDS) level too high 

Refer to dealer for proper water testing 

Cloudy water; foamy water; scum 

Filter not working 

Clean or replace filter 

NOTE: Cloudy water may occur when the ozone generator is started. Filter and backwash as necessary.  

P13 Installation Kit 

PZ2-4 Thru PZ2-162 Series with Bypass / Venturi Injector

  

Description 

Part Number  Quantity 

 

 

 

884 Venturi Injector 

600212 

Plastic Clamp ½” 

20185 

Metal Clamp 1¼” 

20067 

Plastic Clamp ⅝” 

20186 

18 

Polybraid Hose ¼” 

20260 

12” 

Polybraid Hose ⅜” 

20261 

240” 

Clear Hose ¾” 

20264 

120” 

Fitting ½” MPT x ⅜” HB 

20231 

Fitting ½” MPT x ¼” HB 

20230 

Check Valve ½” 

20215 

Fitting ¾” MPT x ¾” HB 

20678 

D12 Installation Kit 

PZ2-4 Thru PZ2-16 Series with Direct Injection

  

Description 

Part Number  Quantity 

 

 

 

Plastic Clamp 

⅝”

 

20186 

20 

Polybraid Hose 

⅜”

 

20261 

240” 

Fitting ½” MPT x ⅜” HB 

20231 

Check Valve ½” 

20215 

Fitting ¾” MPT x ½” FPT 

20303 

Reviews: