ECO MASTER
ADVANCED OXIDATION PURIFICATION
INSTALLATION AND OPERATION MANUAL
PROBLEM
PROBABLE CAUSE
REMEDY
NO LIGHT FROM PROZONE UNIT
NO BUBBLES IN RETURN FITTING OR LINE
(NO INDICATOR OF OZONE)
CLOUDY WATER, FOAMY WATER, OR SCUM
LOOSE WIRING
NO POWER TO UNIT
DEFECTIVE LAMP OR
OTHER INTERNAL COMPONENT
TOO MUCH BACK PRESSURE IN RETURN LINE
UNBALANCED WATER CHEMISTRY
TOTAL DISSOLVED SOLIDS (TDS) LEVEL TOO HIGH
FILTER NOT WORKING
RETURN UNIT TO DEALER
CHECK ALL WIRING CONNECTIONS
CHECK SUPPLY LINE AND RETURN LINE PRESSURES.
RETURN LINE PRESSURE SHOULD NOT BE GREATER
THAN 10 PSI AND SHOULD NOT BE GREATER THAN
SUPPLY LINE PRESSURE. ADJUST ACCORDINGLY.
CHECK READINGS AND BALANCE ACCORDINGLY
REFER TO DEALER FOR PROPER WATER TESTING
CLEAN OR REPLACE FILTER
CHECK VOLTAGE AND POWER SOURCE COMPATIBILITY
TROUBLESHOOTING GUIDE
4
FOAMING GRAPH
The main indicator of a proper installation can be easily verified by observing the outlet fitting (opposite the cord
end) and the hose connected to it. Ideally, you will see a “foam” (bubbles) flowing out of the system. Any
amount of bubbles indicates ozone gas flow, but you want to see at least an amount of bubbles which can be
easily identified by eye. It may helpful to hold the “foaming graph”, behind the clear tubing, to better see the
bubbles. The bubbles should be relatively small and fast moving. If you can visually observe the ozone gas flow
then you have a good balance of flow and pressure differential and your installation should function effectively.