Prozone ECO MASTER Installation And Operation Manual Download Page 4

ECO MASTER

 

ADVANCED OXIDATION PURIFICATION

INSTALLATION AND OPERATION MANUAL

PROBLEM

PROBABLE CAUSE

REMEDY

NO LIGHT FROM PROZONE UNIT

NO BUBBLES IN RETURN FITTING OR LINE

           (NO INDICATOR OF OZONE)

CLOUDY WATER, FOAMY WATER, OR SCUM

LOOSE WIRING

NO POWER TO UNIT

DEFECTIVE LAMP OR

 

OTHER INTERNAL COMPONENT

TOO MUCH BACK PRESSURE IN RETURN LINE

UNBALANCED WATER CHEMISTRY

TOTAL DISSOLVED SOLIDS (TDS) LEVEL TOO HIGH

FILTER NOT WORKING

RETURN UNIT TO DEALER

CHECK ALL WIRING CONNECTIONS

CHECK SUPPLY LINE AND RETURN LINE PRESSURES. 

RETURN LINE PRESSURE SHOULD NOT BE GREATER

THAN 10 PSI AND SHOULD NOT BE GREATER THAN

SUPPLY LINE PRESSURE. ADJUST ACCORDINGLY.

CHECK READINGS AND BALANCE ACCORDINGLY

REFER TO DEALER FOR PROPER WATER TESTING

CLEAN OR REPLACE FILTER

CHECK VOLTAGE AND POWER SOURCE COMPATIBILITY

TROUBLESHOOTING GUIDE

4

FOAMING GRAPH

The main indicator of a proper installation can be easily verified by observing the outlet fitting (opposite the cord 

end) and the hose connected to it. Ideally, you will see a  “foam” (bubbles) flowing out of the system. Any 

amount of bubbles indicates ozone gas flow, but you want to see at least an amount of bubbles which can be 

easily identified by eye. It may helpful to hold the “foaming graph”, behind the clear tubing, to better see the 

bubbles. The bubbles should be relatively small and fast moving. If you can visually observe the ozone gas flow 

then you have a good balance of flow and pressure differential and your installation should function effectively.