10
3.5
Indications and contraindications
The indications for the use of the devices in therapy are shown in chapter 7 for the respective devices.
The devices are contraindicated and must not be used for the conditions listed below:
•
Febrile diseases
•
Current pain at rest or during activity, as well as acute health complaints
•
Existing pain in the musculoskeletal system among other things after stretches, strains, torn
muscle fibers, sprains and disc protrusions
•
Fresh fractures
•
Osteoporosis in continued stages (grade 2 and 3)
•
Hypertension in continued stages (grade 2 and 3 according to WHO)
•
Artificial joint replacement at the knee and/or hip joint with unstable anchorage
•
Severe neurological diseases with a tendency to muscle spasms
•
Abdominal wall or inguinal hernia
•
Pregnancy from the 2nd trimester
•
Heart failure and coronary heart disease. Patients with high blood pressure may only use the
device after consultation with their physician
.
3.6
Patient population
The devices are intended for professional use in health care facilities such as orthopedic and
physiotherapy departments in hospitals, rehabilitation clinics, etc. Depending on the indication, health
condition of the patient and treatment goal, the devices can be used in any phase of rehabilitation.
3.7
Clinical benefit
Compass
®
600 devices support physiotherapeutic interventions. The clinical benefit for the patient lies
in the complementary use of the devices and the resulting improved muscle stabilization.
3.8
Responsible operation
These operating instructions are intended for the operator and the qualified personnel. All people who
work on the device must be trained in its use and must have read and understood the operating
instructions including the safety chapter.
Personnel must be informed before therapy begins and at regular intervals about the nature and scope
of activities and about possible hazards such as any warnings.
Instruction on the equipment (therapist, trainer, fitness trainer) and monitoring (therapist, sports
therapist, fitness trainer) may only be carried out by trained personnel. Authorization of the operator is
required.
Adjustments must not be operated under load. Before each adjustment, make sure that there is no load
from a lifted weight block. This may impair the permanent functionality of the components.
Summary of Contents for Compass 600
Page 1: ...compass 600 User manual ...
Page 20: ...20 Leg fixation 105 10 85 6 à 10 ...