ProxiMity UVC-CM Product Manual Download Page 1

 Made in the U.S.A

proximitysystems.com/uvclean

Proximity 

UVC-CM

PRODUCT GUIDE

REV H /2021

Summary of Contents for UVC-CM

Page 1: ...Made in the proximitysystems com uvclean Proximity UVC CM PRODUCT GUIDE REV H 2021 ...

Page 2: ... A REV H 2021 Proximity UVC CM CONTENTS 1 Quick Guide 2 Safety Disposal 3 Set Up 4 How It Works 5 How It Works Setting Changes 6 How It Works Audit Records 7 Warranty Terms ...

Page 3: ...ection for UV auto shut off feature Control the on off of the LED task Light DC 5V supply included 5mm jack Retrieve cleaning cycle information stored internally 4 Power Receptacle Blue Blink Bulb Failure White On Stand By Blue Cleaning 2 1 3 5 4 Rear View Front View UV C Unit White On Stand By Blue Cleaning Blue Blink Bulb Failure A PC operating Windows 7 or newer A USB port 3 0 or newer if using...

Page 4: ...not attempt to disassemble this product Nor is it serviceable Warranty will be void This UV bulb contains mercury in very small amounts Precautions should be used to prevent breakage Mercury may cause injury if swallowed and is known to cause reproductive harm Dispose of this product responsibly per regulations Do not expose this product to water liquids or moisture Electricity is present UV C can...

Page 5: ...is on Install 2 screws until GJrm One short and one long Step 1 Step 2 Install the second portion of the clamp bracket Up and then slide to back Step 3 Install the first portion of the clamp bracket It will be loose until all assembly complete at Step 7 Install 2 supplied Long screws Locate clamping screws Do not thread completely so you may clamp the intended mounting surface Long Short 0 degrees...

Page 6: ...er the motion sensor has communicated an absence of movement Factory set to 4 minutes Wait Time Downtime scheduled between cleaning cycles that are unrelated to motion sensor activity Factory set to 60 minutes Operation Timing 16 0 10 0 22 0 5 0 4 3 example height 0 o 15 o Rotational Adjustment for Tilt Max Disinfection or reduction requires the light to be in contact with the surface for at least...

Page 7: ...to your local time by mousing over and clicking the Set Device To Local Date Time button located on the Home tab Date Time 1 2 Required Plug in micro USB data cable For data transfer to PC Downloaded software from the product website is also required Follow direction below if data retrieval from the device is needed or changes to the device pre set times in needed Product is set to factory setting...

Page 8: ...ntly eliminate the logged events stored within the UV Clean device memory Save to File This will export the cleaning data to a csv file for use on a PC The following information is included Date Time Duration The length of clean time page 4 Status The UV Clean device s function for the logged event Completed Clean cycle ran duration of clean time setting Interrupted Motion detected during clean cy...

Page 9: ... at any time without incurring any obligation to make the same or similar changes to previously designed built and delivered units Proximity reserves the right to charge for replacement warranted parts or those parts which are found to have failed due to unauthorized modification or alteration of the product improper installation inadequate inspection or maintenance damage in transit or abuse of t...

Reviews: