41
UPC-E1
Read: Format
System character “1”
Data digits (6 digits)
Check digits
Check digit verification: The check digit is optional and made as the sum of the numerical value of the
data digits.
Check digit trans.: By setting Enable, check digit will be transmitted.
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
Supplement digits:
Format
System character “1”
Data digits (6 digits)
Check digit
Supplement digits 2 or 5
Truncation/Expansion:
Truncate leading zeros- Refer to Truncation/Expansion of UPC-A.
Expand to EAN-13- It extends to 13-digits with “0” digits when the feature is set to be enabled.
Expand to UPC-A- It extends to 12-digits when the feature is set to be enabled.
Truncate system character- The system character “1” of UPC-E1 data can be truncated when the feature
is enabled.
Summary of Contents for is900
Page 1: ...User Manual ...
Page 2: ......
Page 10: ...viii ...
Page 17: ...5 Decode zone High density series Long range series ...
Page 18: ...6 Dimensions ...
Page 41: ...29 SETUP Option bar code Option Alpha entry Caps Lock override Disable Enable 00 01 END ...