7 Technical data 

 
7.1 Device data 
 
Basic information 
1 System 

voltage 

12V 

2 Continuous 

power 

600VA 

Peak surge output power 

1200VA 

4 Max 

efficiency 

92% 

5 Average 

efficiency 

>89% 

Own consumption standby 

9Watt 

DC input side 
1 Battery 

voltage 

10.5-14.9V 

2 Reconnection 

Voltage 

12.5V 

Max. Input current 

56Amp @ 600W 

AC output side 
1 Output 

voltage 

230V 

AC 

±

 10% 

2 Output 

Frequency 

50 

±

 1 Hz 

3 Output 

current 

2.6Amp 

Total Harmonic Distortion(THD) 

<4% 

Safety 

Electrical protection 

Over voltage protection of input, 
over current protection of output, 
over temperature protection 

Operation conditions 
1 Ambient 

temperature 

-20

~+45

 

Cable length battery/AC 

1.5m/1m   

Degree of protection 

IP31 

4 Dimensions(LxWxH) 

336x203x80mm 

5 Weight 

2.4Kg 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

8

Summary of Contents for TSW600 Basic

Page 1: ...Operating Manual TSW600 Basic...

Page 2: ......

Page 3: ...4 1 Mounting 4 4 1 1 Mounting location 4 1 2 Mounting the inverter 4 2 Connection 5 5 5 5 6 4 2 1 AC output of the inverter 4 2 2 Connecting the battery to the inverter 5 Operation 6 7 5 1 Switching t...

Page 4: ...PV battery systems They convert the battery s DC voltage into pure sine wave AC voltage this can provide nice power to any normal AC appliances such as consumer electronics tools household appliances...

Page 5: ...1 About this manual These instruction manual are part of the product z Read these operating instructions carefully before use z Keep them over the entire lifetime of the product z Pass them on to any...

Page 6: ...ned in locations where inflammable gases and vapors can occur in dusty environments or in the vicinity of solvents z No open fires flames or sparks in the vicinity of the batteries z Ensure that the r...

Page 7: ...Aviation plug with 1 m cable 230V AC 50Hz Output 4 Fuse box 35A X 2pcs 5 Battery connector Black Negative polarity Connect to Black cable with Ring connector Approx 1 5m long 6 Battery connector Red P...

Page 8: ...moment z Hang the inverter on the two screws and mark the lower holes z Remove the inverter and drill the two lower holes z Insert the dowels z Hang the inverter on the two upper screws and screw in t...

Page 9: ...tery 10 5 14 5V 5 Operation The inverters are equipped with a standby system To avoid unnecessarily discharging the battery in this operating mode switches off the inverter manually when no consumer d...

Page 10: ...load protection The inverter switch off automatically when output power is higher than 650Watt Inverter will automatically restart after 5 seconds if the output power still higher than 650Watt it will...

Page 11: ...on Voltage 12 5V 3 Max Input current 56Amp 600W AC output side 1 Output voltage 230V AC 10 2 Output Frequency 50 1 Hz 3 Output current 2 6Amp 4 Total Harmonic Distortion THD 4 Safety 1 Electrical prot...

Page 12: ...ry Alarm Battery isn t connect tightly Cleaning and reconnect Over load protection Restart inverter if the problem can t be solved after restart reduce the load or change a powerful inverter Deep disc...

Page 13: ...on of the system may result in damage to property and as a result to bodily injury Therefore we assume no responsibility and liability for loss damage or costs which result or are in any way related t...

Page 14: ...n Hong Kong Tel 852 2330 8842 Fax 852 2330 8843 E mail sales provistahk com Serial Number of product Comments waste electrical products should not be disposed of with household waste please recycle wh...

Page 15: ......

Page 16: ......

Reviews: