background image

10 minutes before use, especially at high wattage 

settings.
3. Normal charge times from empty are 3-5 hours 

for the XPV (standard battery).
4. The XPV should be almost fully charged upon 

delivery from Protovapor. It can be used immedi-

ately.

General operation

1. Attach atomizer device containing e-juice to the 

connector at the top of the unit. DO NOT OVER-

TIGHTEN!
2. Adjust wattage of device using up/down con-

trol switch under the fire button. Start low if you 

do not know the wattage at which your atomizer 

works best.
3. Depress firing button and hold while drawing on 

the atomizer device.

DNA 30D INFORMATION

Your XPV is powered by the DNA 30D board by 

Evolv Vapor.

Display information

Watt setting (W):

 The power level currently set 

on the DNA 30D.

Battery indicator (Icon): 

The current state of 

charge of the battery.

Volts display (V): 

The current or most recent out-

put voltage being supplied to the atomizer.

Ohms display: (

Ω

)

 The resistance of the atomizer 

attached to the device. This is measured only when 

the unit is supplying power to the atomizer. At 

other times, it shows the most recent measurement.

Other modes

Locked mode: 

Pressing the fire button five times 

with less than .7 seconds between presses will 

cause the device to enter Locked mode. In Locked 

mode, the device will not fire and the output power 
will not adjust accidentally. While in Locked mode, 
the screen will be off, except that pressing a but-
ton will show “Locked, Click 5X”. To exit Locked 
mode, press the fire button 5 times.

Stealth mode: 

While locked, pressing the fire and 

down control simultaneously for five seconds will 
switch to stealth mode. In this mode the display 
is off. It will still show error messages and the 
“Locked, Click 5X” advisory. To switch back to nor-
mal display mode, from locked mode press the fire 
and down control simultaneously for 5 seconds. 
This setting is stored to internal flash memory, and 
remains if power is removed.

Right Mode and Left Mode: 

While locked, hold-

ing the fire and up control simultaneously for 5 
seconds flips the display. This allows for maximum 
flexibility, as well as accommodating left handed 
vapers. This setting is stored to internal flash 
memory, and remains if power is removed.

Power Locked mode: 

Pushing the up/down con-

trol switch in for 4 seconds will place the device in 
Power Locked mode. In this mode, the mod will op-
erate normally, but you will not be able to change 
the power setting. This mode prevents accidental 
power level changes. To exit Power Locked mode, 
push the control switch in for 4 seconds. 

Error Messages

The DNA 30D will indicate a variety of error 
states. 

Note:

 It is normal for the DNA 30D to oc-

casionally display one or two error messages upon 
wake-up from sleep. These can be ignored.

Check Atomizer: 

The DNA 30D does not detect 

an atomizer, or the atomizer has shorted out.

Check Battery: 

The battery is below 3.1 volts. It 

probably needs to be charged.

Weak Battery: 

The battery sags excessively when 

firing. This typically means the user is not using a 
high rate battery, or the battery is old and de-
graded. It can also mean the battery is not making 
good contact.

Too Hot: 

The DNA 30D has onboard temperature 

sensing. It will shut down and display this message 
if the internal temperature becomes excessive.

PROTOVAPOR

XPV

Reviews: