P2_PANTHER_user manual_ work basis_EN_03 - 07/11 - Protherm
- 40 -
NEED HELP?
Description
Units
PANTHER 25 KTO
Gas category
II2H3P
Distribution
C12, C32, C42, C52, C82, B22
Ignition
electronic
Power/ fuel
natural gas
propane
Maximum thermal consumption
kW
26,5
Minimum thermal consumption
kW
10,6
Maximum thermal output
kW
24,6
Minimum thermal output
kW
8,9
Ef
fi
ciency
%
92,7
Maximum gas consumption
m
3
/h
2,80
Minimum gas consumption
m
3
/h
1,12
Maximum gas consumption
kg/h
2,05
Minimum gas consumption
kg/h
0,82
NO
x
classi
fi
cation
3
Gas pressure
Inlet pressure
mbar
20
37
Membrane diameter
mm
5,80
5,95
Maximum pressure in discharge nozzles
mbar
12,4
32,7
Minimum pressure in discharge nozzles
mbar
1,9
5,0
Discharge nozzle diameter
mm
1,20
0,73
Heating
Maximum working pressure
bar
3
Minimum working pressure
bar
0,5
Recommended operating pressure
bar
1 - 2
Temperature range
°C
38 - 80
Expansion tank
l
7
Maximum pressure in the expansion tank
mbar
3
Hot water
Maximum pressure
bar
-
Minimum pressure
bar
-
Minimum HW
fl
ow
l/min
-