PROTEOR 5G50 Instructions For First Start And Use Download Page 1

5G5099-05/07 P1/12 

 
 
 
 

FOUR 5G50 

NOTICE DE MISE EN SERVICE ET D’UTILISATION (P2-5) 

 
 
 
 
 
 

OVEN 5G50 

INSTRUCTIONS FOR FIRST START AND USE (P6-9) 

        Service commercial / Customers service 

 
 

- téléphone :  

+33 (0)3 80 78 42 10 

 

- télécopie :  

+33 (0)3 80 78 42 15  

 

- e-mail :   [email protected] 

 

- adresse :   PROTEOR HANDICAP TECHNOLOGIE 

                            Service Orthopédie 
                            6, rue de la Redoute 
                            Z.I. Saint-Apollinaire 
                            B.P. 37833 - 21078 DIJON Cedex - France 
                            www.proteor.com 
 

Summary of Contents for 5G50

Page 1: ...FIRST START AND USE P6 9 Service commercial Customers service t l phone 33 0 3 80 78 42 10 t l copie 33 0 3 80 78 42 15 e mail ht orthopedie proteor com adresse PROTEOR HANDICAP TECHNOLOGIE Service O...

Page 2: ...la tension disponible au r seau Une erreur de commutation endommagerait le four Si le commutateur est dans la position 400V et que la ligne lectrique de l utilisateur est bien en 400V tri il n y a ri...

Page 3: ...eur proc der de la fa on suivante 1 Simultan ment appuyer sur le bouton rouge et tourner le bouton noir pour afficher la temp rature d sir e 2 Rel cher le poussoir rouge Le mat riel est talonn par des...

Page 4: ...produits pour lesquels il a t initialement con u Ne JAMAIS r chauffer de produits destination alimentaire Pr sence de tension dans l armoire lectrique Avant chaque intervention lectrique positionner...

Page 5: ...C dans l armoire lectrique Si le probl me persiste pr ve nir le SAV PROTEOR La temp rature affich e au r gulateur est inf rieure la consigne Tester KM1 v rifier la pr sence de tension en sortie Mettre...

Page 6: ...voltage A wrong switch position would damage the oven If the switch is turned on 400V for a user s electrical power line of 400 V three phase do not modify anything In the case of a user s electrical...

Page 7: ...the regulator 1 Simultaneously press the red button and turn the black one to display the required temperature 2 Release the red push button The equipment is gauged during tests after its manufacturi...

Page 8: ...s for which it has been initially designed NEVER use it to re heat food Voltage in the electrical cabinet Before each action on the electrical system position the dis connecting switch on 0 Important...

Page 9: ...net If the problem remains after checking inform PROTEOR s after sales service The temperature displayed on the regulator is lower than the recommended one Test KM1 Check the pres ence of voltage at i...

Page 10: ...5G5099 05 07 P10 12...

Page 11: ...5G5099 05 07 P11 12...

Page 12: ...5G5099 05 07 P12 12...

Reviews: