14
n02
User
parameters
The time interval of
auto restart cooling
Adjustable range:
3-40minute
5
n03
User
parameters
The time interval of
auto restart fresh
Feature enable,
adjustable range:
30-120minute
n04
User
parameters
The time interval of
auto restart Pre
cooling
Feature enable,
adjustable range:
1-30minute
5
F00
Factory
parameters
Low voltage
protection
Adjustable range:
180-220V
190
F01
Factory
parameters
Motor type
37:370W
55:550W
75:750W
110:1100W
According
to motor
power
F02
Factory
parameters
Pre cooling setting
0
:
No pre cooling
1
:
Single compressor
2
:
Double compressor
According to
pre cooling
function
F03
Factory
parameters
Refrigerating switch
for
refrigerating
cylinder
ON: open the
preservation function
OFF: close the
preservation function
OFF
F04
Factory
parameters
Current coefficient
Adjustable range: 80-120 100
F05
Factory
parameters
Counter function
ON: open count function
OFF: turn off counting
function
ON
F06
Factory
parameters
Air pump action
delay
Adjustable range
:
3-30s
10
F07
Factory
parameters
Clear counting
function
ON: available to clear
the count
OFF: cannot to clear the
count
ON
F08
Factory
parameters
Action time of
pressure balancing
solenoid valve
Adjustable range
:
1-60s
5