background image

ADMISSIBLE TIME OF USE

There is no limitation of time of use the retractable fall arrester  on condition that periodic inspections are regularly 
carried out.

The working cable/webbing snap hook must be connected only 
to frontal or dorsal attachment point of full body harness. Full 
body harness must conform to EN 361.
Always protect the gate of the snap hook against accidental 
opening with locking gear.

CONNECTING THE 

FALL ARRESTER

 TO STRUCTURAL ANCHOR POINT

PRE-USE INSPECTION

Before each use, a person who is going to use  the 

fall arrester

shall

 

carry out a close visual examination of the retractor’s 

elements (case, snap hook including fall indicator, handle, working 
webbing, ) in respect of mechanical, chemical and thermal 
defects. The user has to check the retractor functioning by 
dynamic pulling the working webbing. The webbing should block 
and stops pulling out. After releasing the webbing, the retractor 
should pull in the webbing. In the case of fall indicator be 
destroyed/deformed or any defect of retractor parts or any doubt 
on correct condition of the device - do not use it. 

USAGE

D

uring use the

 fall arrester should

 be protected from a contact with oils, acids, solvents, basics, open fire, hot 

metal drops and sharp edges. During working on the lattice constructions we should avoid interleaving the working 

webbing

 between the individual construction elements. We should avoid using the device in the dust laden and 

gre

a

sy environment.

 U

sing the 

fall arrester

, in connection with fall arrest system, must be compatible with manual 

instructions of the fall arrest systems and obligatory standards:

 

-  EN361

-

for the safety harness

-  EN362 -for the 

connectors

; -  EN795 -for anchorages. 

PERIOD

IC

 INSPECTIONS

 

After each 12 months of utilization the fall arrester 

must be withdrawn from use to carry out 

manufacturer's

 detailed 

inspection

.

 The inspection must be carried out by 

the fall arrester's manufacturer or his certified representative only.

During 

this inspection

 will be established admissible time of 

the fall arrester

 use till next

 manufacturer's 

 

inspection.

The result of inspection must be recorded in Identity Card.

!

personal protective equipment shall only be used by a person trained and competent in its safe use.

!

personal protective equipment must not be used by a person with medical condition that could affect the safety 
of the equipment user in normal and emergency use.

!

a rescue plan shall be in place to deal with any emergencies that could arise during the work.

!

it is forbidden to make any alterations or additions to the equipment without the manufacturer's prior written 
consent.

!

any repair shall only be carried out by equipment manufacturer or his certified representative.

!

personal protective equipment shall not be used outside its limitations, or for any purpose other than that for 
which it is intended.

!

personal protective equipment should be a personal issue item.

!

before use ensure about the compatibility of items of equipment assembled into a fall arrest system. Periodically 
check connecting and adjusting of the equipment components to avoid accidental loosening or disconnecting of 
the components.

!

it is forbidden to use combinations of items of equipment in which the safe function of any one item is affected 
by or interferes with the safe function of another.

!

before each use of personal protective equipment it is obligatory to carry out a pre-use check of the equipment, 
to ensure that it is in a serviceable condition and operates correctly before it is used.

!

during pre-use check it is necessary to inspect all elements of the equipment in respect of any damages, 
excessive wear, corrosion, abrasion, cutting or incorrect acting, especially

 in 

retractable fall arresters - cable or 

webbing, retractor and brake proper acting, casing, energy absorber, connector;

!

regular periodic inspections are the essential for equipment maintenance and the safety of the users which 
depends upon the continued efficiency and durability of the equipment.

!

during periodic inspection it is necessary to check the legibility of the equipment marking. 

!

it is essential for the safety of the user that if the product is re-sold outside the original country of destination the 
reseller shall provide instructions for use, for maintenance, for periodic examination and for repair in language of 
the country in which the product is to be used.

!

personal protective equipment must be withdrawn from use immediately when any doubt arise about its 
condition for safe use and not used again until confirmed in writing by equipment manufacturer or his 
representative after carried out the detailed inspection.

,

!

a full body harness

 conformed to EN 361

 is the only acceptable body holding device that can be used  in a fall 

arrest system.

!

in full body harness use only attaching points marked with big letter "A" to attach a fall arrest system.

!

the anchor device or anchor point for the fall arrest system should always be positioned, and the work carried 
out in such a way, as to minimise both the potential for falls and potential fall distance. The anchor device/point 
should be placed above the user . The shape and construction of  the anchor device/point shall not allowed to 
self-acting disconnection of the equipment. 

I

t is recommended to use certified and marked structural anchor 

point complied with E

n

795.

THE ESSENTIAL PRINCIPLES OF USE OF PPE  AGAINST FALLS FROM A HEIGHT

WITHDRAWN FROM USE

The fall arrester 

must be withdrawn from use immediately when any doubt arise about its condition for safe use 

and not used again until confirmed in writing by 

device

 manufacturer or his 

certified 

representative after carried out 

the detailed inspection.

 The fall arrester 

must be withdrawn from use immediately and 

sent to the device 

manufacturer of his certified representative to carry out detailed inspection 

when it ha

s

 been used to arrest a fall

 

(especialy when the snap hook indicator is deformed or destroyed). 

Any repair or service operation shall only be 

carried out by fall arrester manufacturer or his certified representative.

The fall arrester must be connected to a structural anchor point by 
its connecting handle using a connector complying with EN362 or 
an anchor device complying with EN795 standard.
Structural anchor point should be situated above the job place and 
have static resistance min. 12kN. The shape of the structural 
anchor point should not let self-acting disconnection of the device. 

The retractable fall arrester shall be installed above the operator. 
When the device is installed in the vertical line above the user 
the minimal clearence distance “z” below working level shall be 
not less than 1,5 m. 
When the cable of the retractable fall arrester is deflected from 
vertical line a pendulum effect occurs during fall arresting. In 
order to minimise the pendulum effect the cable deviation angle 
from vertical shall never exceed 40°.  For this purpose the user is 
permitted to move laterally through distance “l” not greater than 
1/2 “v” .
The clearance distance bellow working level must be greater 
than 1,5 m+ lateral distance “l”.

STRUCTURAL ANCHOR POINT REQUIRMENTS

v

retractable type 

fall arrester

retractable type 

fall arrester

anchor point

anchor point

l

z

working 
level

pendulum 
effect

ground 
level

o

max 40

CONNECTING THE 

FALL ARRESTER

 

TO FULL BODY HARNESS