UNDERSTANDING BUTTONS & LED INDICATORS 

Item 

Behavior  

Power Button 

1. Short press 0.5 - 1 sec on/off all back outlets (G1 - G4) 
2. Long press 10 second factory reset and in pairing/setup mode 

Power Button LED 

1. Flashing: (a) Factory reset and in pairing/setup mode  
2. Solid LED: Connected, relay ON 
3. No LED: Connected, relay OFF 

Reboot Button 

1. G1 outlet and LED always on 
2. Short press reboot button 0.5 - 1 sec, relay OFF 3 secs and back ON 

LCD Dimmer Button 

1. Short press cycle through dimmer 10,35,70,100% 

Voltage/Current 
Button 

1. Short press cycle through Voltage or Current readings 

G1 - G4 LED 

1. Light On: Relay on 
2. Light off: Relay off 

Protected / Clean 
Power 

1. Light On: Protected / Clean Power 
2. Light off: Surge protection failed and must replace device 

Ground OK 

1. Light On: Ground  
2. Light Off: No Ground 

Reverse Polarity 

1. Light off: Normal  
2. Light On: Reverse polarity detected, check wiring 

Unsafe Voltage 

1. Light off: Normal Voltage 
2. Light On: Unsafe voltage detected 

 

SPECIFICATIONS 

 

Surge suppression: 

 

Max. energy dissipation: 6480 joules 

 

Load rating: 15 amps 

 

Line voltage: 125V AC @ 60 Hz 

 

Over & Under voltage protection: Yes (auto shut off) 

 

Over voltage 135V auto shut off 

 

Under voltage 95V auto shut off 

 

USB output: 4 ports 5V/2.4A each pair 

Summary of Contents for PR-91W

Page 1: ... surge protection Electronic noise filtration 70dB 8ft power cord with 360 degree rotating plug SYSTEM REQUIRMENTS Home Wi Fi network 2 4Ghz Elac ProTek app free download at Elac app url PACKAGING CONTENTS Surge protector Quick Setup Guide OVERVIEW USING YOUR BLUETOOTH SMART SURGE PROTECTOR 1 Connect your mobile to Wi Fi network Note Must be same network you re planning to connect PR 91W to 2 Down...

Page 2: ...Button 1 Short press cycle through Voltage or Current readings G1 G4 LED 1 Light On Relay on 2 Light off Relay off Protected Clean Power 1 Light On Protected Clean Power 2 Light off Surge protection failed and must replace device Ground OK 1 Light On Ground 2 Light Off No Ground Reverse Polarity 1 Light off Normal 2 Light On Reverse polarity detected check wiring Unsafe Voltage 1 Light off Normal ...

Page 3: ...ent has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe...

Page 4: ...and operated with minimum distance 20cm between the radiator and your body This radio transmitter IC 3653A PR91W has been approved by Innovation Science and Economic Development Canada to operate with the antenna types listed below with the maximum permissible gain indicated Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are str...

Reviews: