7.0 Trouble Zone Input
Trouble zones are used to monitor the status of the
Standard 16 PGM Output Expander and in most cases not
physically connected to the an external zone. An example
is trouble zone 8 is the communication trouble zone, this
will open when the Standard 16 PGM Output Expander is
removed from the system or has lost communication.
Trouble Zone
Function
PXXXX:01
Tamper Input. Normally Closed
Contact.
PXXXX:02
Power Fault. Power to the Standard
16 PGM Output Expander is below
10.5VDC.
PXXXX:03
Reserved.
PXXXX:04
Reserved.
PXXXX:05
Reserved.
PXXXX:06
Reserved.
PXXXX:07
Reserved.
PXXXX:08
Device Communication. The
Standard 16 PGM Output Expander
has lost communications and is no
longer online with the Protégé
System Controller.
8.0 Error Messages
When the Standard 16 PGM Output Expander is powered
up and starts communicating with the controller it is
possible that the Standard 16 PGM Output Expander can
be denied access to the module network. This is a normal
part of the Protégé System.
In normal operation the status indicator will flash rapidly
while it is attempting to contact the controller. When it is
online it will turn flash at one second intervals. When an
error occurs the status indicator will FLASH with the error
code number. The error code number is shown with a
250ms ON and OFF period (duty cycle) with a delay of 1.5
seconds between each display cycle.
1 Flash - Internal Error
An internal error has occurred on the Standard 16 PGM
Output Expander. Please contact your distributor.
2 Flash - Version Error
The version of the Standard 16 PGM Output Expander is
not correct for the System Controller. The firmware can be
updated. Please contact your distributor.
3 Flash - Keypad Address Too High
The address of the Standard 16 PGM Output Expander that
is programmed is beyond the maximum number of
Standard 16 PGM Output Expander that are allowed to
connect to the system controller. You may also be able to
adjust the controller profile to increase the Standard 16
PGM Output Expander module capacity.
4 Flash - Duplicate Device Address
The address of the Standard 16 PGM Output Expander is
already programmed in to the address location.
5 Flash - Security Violation
The system controller has security enabled and no devices
can be added to the system.
6 Flash - Invalid Serial Number
The Standard 16 PGM Output Expander has an invalid
serial number programmed and can not be registered on
the system. Return the Standard 16 PGM Output Expander
to your distributor.
9.0 Specifications
Power Supply
Voltage
12VDC (10.5 - 14.0VDC)
Current 59mA
(Typical)
Communication
RS-485
Module
Network
Outputs
PGM Output
16 (50mA Max) Open Collector
Inputs
Tamper
1 (Normally Closed Contact)
Trouble Zone
8
Temperature
Operating
5˚- 55˚ Celsius
41˚ - 131˚ Fahrenheit
Humidity
0%-85%
(Non-Condensing)