Important
! The distance between the reed contact and the
magnet casing must be less than 7 mm.
3. Insert the magnet and close the compartment using the
upper part of the casing.
Please ensure that the individual components are attached
securely and correctly. Replace the batteries immediately if
the battery LED (9) on the transmitter illuminates.
MINIMUM OPENING ON WINDOW
This is determined by:
a. The throughput of the air extraction device in m³/h
b. The size of the window to be opened in m²
c. The size of the gap at the window in cm (see Table 1)
TRANSMITTER ASSEMBLY
Remove the battery compartment cover (10) by applying
slight pressure and at the same time sliding it in the
direction of the arrow.
Place the batteries (3x AAA alkaline) in correct pole direction
into the window transmitter. Close the battery compartment
cover correctly.
1. Mount the window transmitter (2) with reed contact
(2a) at the top window frame on the window to be mo-
nitored. Use the included packer parts (U) if the height
needs adjustment. Decide on the mounting location
and clean the adhesion surfaces. Mount the window
transmitter and the corresponding reed contact at the
chosen location using the included double-sided adhesive
pad. Please ensure that the individual components are
attached securely and correctly.
2. Then attach the magnet casing (3) on the window leaf
at the correct location using the included double-sided
adhesive pad.
0,2
2000
199
246
294
342
389
437
485
532
0,3
3000
252
311
369
427
486
544
603
661
0,4
4000
297
365
432
500
567
635
702
770
0,5
5000
337
413
488
563
639
714
790
865
0,6
6000
373
456
538
621
704
786
869
951
0,7
7000
406
495
585
674
763
852
942
1031
0,8
8000
437
532
628
723
819
914
1009
1105
0,9
9000
466
567
668
770
871
972
1073
1174
1
10000
493
600
707
813
920
1027
1133
1240
1,1
11000
519
631
743
855
967
1079
1191
1302
1,2
12000
544
661
778
895
1012
1128
1245
1362
1,3
13000
568
690
811
933
1055
1176
1298
1419
1,4
14000
591
717
843
970
1096
1222
1348
1475
1,5
15000
613
744
874
1005
1136
1266
1397
1528
m
2
cm
2
5 cm
6 cm
7 cm
8 cm
9 cm
10 cm
11 cm
12 cm
Extent of window opening
Calculation table to determine the minimum
opening of your window (Table 1)
Summary of Contents for AS-500
Page 1: ...AS 500 BETRIEBSANLEITUNG OPERATING INSTRUCTIONS ...
Page 2: ...AS 500 DEUTSCH 2 2a FENSTER SENDER 3c 3b 3a 9 10 7 2 8 7 mm ...
Page 3: ...DEUTSCH AS 500 3 1 5 ZENTRALE EMPFÄNGER 6 4 5 ...
Page 9: ...DEUTSCH AS 500 9 ...
Page 10: ...AS 500 ENGLISH 10 2a TRANSMITTER 3c 3b 3a 9 10 7 2 8 7 mm ...
Page 11: ...ENGLISH AS 500 11 1 5 RECEIVER 6 4 5 ...
Page 17: ...ENGLISH AS 500 17 ...
Page 18: ......
Page 19: ......