TERMINAL BLOCK CONNECTIONS

All the connections must be done without power supply.

 

EARTH TERMINAL BLOCK CONNECTIONS

 

Connect the yellow/green motors cable to earth terminal 

A

 .

 

Connect the yellow/green network cable to earth terminal 

B

.

TERMINAL BLOCK 2 CONNECTIONS

1-8 

Start control

 normally open (NA) for button, key selector , radio receiver or Timer clock connection. 

 

The Start control starts the programmed running cycle. 

2-8 

Stop control

 normally closed (NC). Emergency button.  

 

When pressed the gate stops immediately. 

 

In Opening phase and Break-time: at the first impulse the gate closes.

 

In Closing phase: at the first impulse the gate opens. 

 

If, temporarily, the Stop contact is not used, link terminal 2 with terminal 8. 

3-8 

Input of one safety photocell in closing phase.

 

Input of safety rubber edges and of safety photocell in closing phase.

 

Input of several safety photocells in closing phase

.

 

The receiver contacts must be connected in series. Normally closed (NC). 

 

In opening phase: does not work

 

In closing phase: Stop, break-time for 2 seconds, opening phase again.

 

If, temporarily, the photocell contacts are not used, link terminal 3 with terminal 9. 

3-9 

Input only for safety rubber edges in closing phase.

 

The contacts must be connected in series if there is more than one safety rubber edge. 

 

Normally closed (NC).

 

In opening phase: does not work. 

 

In closing phase: Stop, break-time for 2 seconds, opening phase again. 

4-8 

Input for safety photocells in opening phase (for sliding gate).

 

Normally closed (NC).

 

In opening phase: Stops and changes direction for 3 seconds

 

In closing phase: does not work

 

If you also want to connect the safety rubber edges, you must connect in series their contacts with the photocell ones.

 

If, temporarily, the photocell contacts are not used, link terminal 4 with terminal 9.

 

4-9 

Input safety rubber edges in opening phase (for sliding gate). 

 

Normally closed (NC). 

 

In opening phase: Stops and changes direction for 3 seconds

 

In closing phase: does not work

 

Using more than one safety rubber edges, the contacts must be connected in series. 

5-8 

Limit switch input in closing phase. 

6-8 

Limit switch input in opening phase. 

7-8 

Pedestrian start input

. Normally open (NA).Only one leaf start to open  

8-10  Output for photocell receiver power supply. 
 

Output for extra 24V dc accessories power supply.

 

With all Standard accessories included 100 m A are still available for extra accessories. 

9-10  Output for photocell transmitter power supply. 
11-12  Blinker intermittent output. 

24V  20W max

TERMINAL BLOCK 3 CONNECTIONS

Motor  M1-  output

 

The motor is assembled to be fixed on the right side of the gate (looking from inside).
If you need to fix it on the left side of the gate and the motor has 

electromechanical limit switch

 system, you have to swap 

motor wires 13 with 15 and limit switch wires 5 with 6. Capacitor between plugs 13 and 15. 

If you need to fix it on the left side of the gate and the motor has 

magnetic limit switch

 system, you have to swap motor wires 

13 with 15 and keep unchanged the limit switch wires. 

PLEASE PAY ATTENTION TO REVERSE THE MAGNET SUPPORTS

.

Capacitor between plugs 13 and 15. 

 

TERMINAL BLOCK 4 CONNECTIONS

Power input 230-240 Vac - 50/60 Hz. (19=Neutral - 20=phase)

13- 14-15

19-20

24V dc

START

STOP

FCC

FCA

1

2

3

4

5

6

7

8

9

10

11

12

Terminal block 2

Blinker

24Vmax20W

Com.-24PhotoRX/TX

+24PhotoTX

+24PhotoRX

Common

Pedestrian

Contactphoto1

Contactphoto2

N

L

19

20

Neutral

Phase

Terminal block 4

Open

Closing

13

14

15

M1

Terminal block 3

Capacitor

Com.

AERIAL

RED

BLACK

WHITE

EXTERNAL RADIO PANEL