3.4.6
115V-60Hz
230V-50Hz
24V dc
CONTACT
1
Yellow - Green
EARTH
2
Gr
ey
NEUTRAL
3
Black
Brown
OPENING
4
Brown
Blu
e
CLOSING
ATTEN
T
ION!
Th
e electric plant must be protected by a ground system,
in accordance to the current safety regulations.
Do not let the motor wire stretch during opening and
closing.
Capacitors are provided just with 230V and 115V motors.
Picture
O
Picture
P
Picture
Q
Picture
R
Picture
S
10
ASTER - rev. 13_02_2021
2 cm
3.4.5
F
ixing the gate bracket
Follow the below procedure to determine the bracket position on
the gate:
- Put the gate to CLOSING position.
- Unlock the operator (refer to section 5.2 Manual Operation).
- Extend the inox arm fully.
- Turn back the arm 2 cms. This avoids the motor to “leap forward”
(picture
N
).
- Press the plastic cap with little force, and gently slide it forward
(picture
O
).
- Insert the bracket in the motor and fit the pin (picture
P
).
- Mount the arm of the motor onto the gate. Ensure the arm is
perfectly straight. Check the manual opening of the leaf before
definitively fixing the bracket to make sure the gate can open fully
to your required angle.
- If the bracket position is the correct one, remove the pin (picture
R
) and proceed to definitively fix it.
- Repeat steps shown in picture
P
and
Q
.
NB:
Check the manual opening of the leaf before definitively fixing
the bracket to make sure the gate can open fully to your required
angle.
NB:
If you wish to remove the pin, take the cap off, and push
using a screwdriver (Ø max 4,5 mm) until the pin is out.
Wirings
Atten
tion
!
An incorrect wiring could lead to failures and very
dangerous injuries. Therefore carefully follow the wiring
instructions contained in this manual.
Switch the power and batteries OFF before any wiring
operation
.
The electric plant must be performed by qualified
personnel and must comply with the outstanding
regulations.