Thank you for purchasing this Multifunction Analogue Multimeter. This 
multimeter is perfect for those who prefer to use a galvanometer (analogue 
moving coil meter) to take measurements. It can sometimes be more 
convenient to view an analogue dial over a digital display when values are 
fluctuating too. The 90 x 70mm display area ensures the printed, continuous 
scale is easy to read. With fuse and diode protection, 20 ranges and a 
protective rubber case - this multimeter is great for any level of experience.

Please familiarise yourself with the functions of the multimeter before use. We 
recommend retaining this manual for ease of reference.

•  Improper use of this meter can cause damage, shock, injury or death.
•  Always remove the test leads before replacing the battery or fuses.
•  Before using the meter, please inspect the condition of the test leads and the 

meter itself for any damage. If damage is present, please discontinue use.

•  Do not measure voltage if the voltage on the terminals exceeds 1000V above 

earth ground. 

•  Use great care if voltages are greater than 30VAC RMS. Anything above this 

is considered a shock hazard. 

•  Always discharge capacitors and disconnect power before performing diode, 

resistance or continuity tests. 

•  Remove the batteries from the meter if it will be unused for an extended 

period of time.

Summary of Contents for QM1020

Page 1: ...HFE TEST DECIBEL TEST CAT II 1000V AUDIBLE CONTINUITY LIFETIME WARRANTY Multifunction Analogue Multimeter HOBBYIST...

Page 2: ...PAGE INTENTIONALLY LEFT BLANK...

Page 3: ...urself with the functions of the multimeter before use We recommend retaining this manual for ease of reference Improper use of this meter can cause damage shock injury or death Always remove the test...

Page 4: ...ltage Range 10V 1000V DC Current Range 50 A 250mA Resistance 2k 20M Continuity Yes Transistor Test Yes hFE Amplification Test Yes Diode Test Yes Calibration Adjustment Indicator 10A Input Jack Range M...

Page 5: ...SUREMENT ON OUTPUT TERMINAL 1 Plug the red test lead into the output socket 2 Plug the black test lead into the COM socket 3 Set the range to the chosen range position 4 Connect the test leads to the...

Page 6: ...r ii When working with PNP transistors ensure the P terminal of the tester is connected with the Collector C of the transistor and the N terminal is connected with the Emitter E of the transistor 5 Re...

Page 7: ...ty of the diode and the P terminal to the negative polarity of the diode i For reverse current tests connect the P terminal of the tester to the pos itive polarity of the diode and the N terminal to t...

Page 8: ...0 B 10 x 1 x 1 x 1 x 100 DC Current DC 50 A 2 55mA 25mA 0 25mA 10A B 50 B 250 B 250 B 250 B10 x 1 x 0 01 x 0 1 x 0 001 x 1 Resistance x 1 x 10 x 100 x 1k x 10k A A A A A x 1 x 10 x 100 x 1000 x 10000...

Page 9: ...he correct polarity 4 Put the battery cover back in place and secure with the screws SPECIFICATIONS Security Class Cat II 1000V Basic DCV Accuracy 3 000 DC Voltage 100mV 500mV 2 5V 10V 50V 250V 1000V...

Page 10: ...the suspected defect fault arises and return the product along with proof of purchase to the place of purchase or distributor for assessment Distributor contact details are available on the last page...

Page 11: ...11 PAGE INTENTIONALLY LEFT BLANK...

Page 12: ...Distributed by Electus Distribution Pty Ltd 320 Victoria Rd Rydalmere NSW 2116 Australia www electusdistribution com au Made in China...