Wire one resistor-potentiometer circuit for each output circuit requiring remote level
control.
Turn gain trimpots on chassis full counterclockwise, on all channels having remote
level.control circuits
Set all remote potentiometers to full clockwise position.
Apply AC power to external power transformer.
Adjust each input and output trimpot to required level by rotating trimpots clockwise.
Suggested settings are 1:00 for input gain trimpots, and 12:00
for the master output trimpot.
This alignment procedure will allow the installer to limit the
maximum gain available to the end user.
1-
2-
3-
4-
5-
REMOTE VOLUME CONTROL CONNECTIONS
Note: Models 2000-RVC-IN (Input Remote Control) & 2000-RVC-OP (Output Re-
mote Control) are available to provide the remote control circuits described below.
See next page.