Do not operate the welding/cutting machine in humid environment, otherwise it

may cause electric shock or short circuit accident.

9.

It is strictly forbidden to re-modify the equipment or the attached equipment

related to the operation of the equipment without permission, to avoid accidents.

10.

The disposal of the scrap equipment must comply with the relevant policies and

regulations of the local government.

Warnings

Welding and cutting is a special type of work, with a certain degree of danger.
Professional training, correct operation and necessary protective measures can
effectively avoid and reduce the damage and loss caused by machine accidents.

Personal and others’ safety protection

When welding and cutting equipment is working, it will generate
noise, strong light and high temperature sparks, which will cause
harm to human hearing, eyes and skin. Correct protective measures
and proper operation training are necessary to prevent injury
accidents.

1

Aprotective helmet with a shading filter must be worn to protect the face and
eyes during welding and cutting operations or when watching welding/cutting
operations.

2

Wear a helmet with the correct filter and cover plate to protect the eyes, face,
neck and ears from arcing sparks and bright light during welding operation or
observation. Warn bystanders not to look at the arc and not to expose their
skin in the area of strong light arc or high temperature spark

3

Wear flame retardant gloves, flame retardant welding/cutting overalls, flame
retardant shoes, and welding/cutting helmets or protective caps to protect
against arcing bright lights, high temperature sparks or hot metal particles. A
flame retardant apron is also available to protect against thermal radiation
and high temperature sparks.

4

Hot sparks or metal can get into rolled-up sleeves, trouser legs or pockets.
Before welding/cutting, sleeves and collars should be buttoned, and clothes
with front pockets should not be worn.

Summary of Contents for CTM-160

Page 1: ......

Page 2: ...annot completely exclude the occurrence of accidents The manufacturer and distributors shall not be liable for any direct or indirect joint and several liability for any incidental or consequential da...

Page 3: ...ions Warnings Package and transportation 8 Parameters Product description 9 Working principle 12 Installation and wiring 12 Brief instruction for welding operation 15 Maintenance 19 Common machine mal...

Page 4: ...stallation must be operated by qualified professional and technical personnel 3 The welding and cutting protective equipment used by the operator must be provided by the manufacturer or distributor ap...

Page 5: ...ve measures and proper operation training are necessary to prevent injury accidents 1 Aprotective helmet with a shading filter must be worn to protect the face and eyes during welding and cutting oper...

Page 6: ...mable and explosive items are not allowed to be placed in the welding cutting area Flammable materials that needed to be used in welding cutting process must be covered with flame retardant materials...

Page 7: ...ea cables flashlights electrode stand and power supply 6 Make sure that every part of your body will not contact with the live electrical parts 7 Never stand directly on metal or the ground when have...

Page 8: ...is harmful to human health 1 Keep your head out of the fumes Do not breathe the fumes 2 Keep well ventilation in welding cutting working environment Do not weld or cut in a confined space and there m...

Page 9: ...can be chained or belted to a suitable trolley base wall post or shelf Never fix the cylinder to the work table or machine to avoid they become part of the circuit 4 Ensure that the cylinder valve is...

Page 10: ...0 93 Efficiency 75 Insulation grade H IP grade IP21S Cooling method Air cooling Max cutting thickness mm 15 Package dimensions mm 402 275 320 N W kg 6 0 PRODUCT DESCRIPTION This series inverter plasma...

Page 11: ...nt into 20 KHz alternating current and transmits power through high frequency transformer 1 3 Output the welding current that meets the requirements set after secondary rectification and reactor filte...

Page 12: ...achine for plasma cutting MMA and TIG welding 1 2 Simple appearance design small volume light weight multilayer control circuit board and separation of control system and cooling system ensuring highe...

Page 13: ...asma cutting functions 4 Welding current adjustment knob Rotate to adjust the output welding current 5 MMA welding cable coupling device negative pole connected with earth clamp which then is connecte...

Page 14: ...is 220V 10 with 50Hz or 60Hz frequency Phase unbalance of three phase voltage 5 Model CTM 160 Parameters Value Power supply AC220V 10 50 60Hz 1PH Rated output current 40A CUT 180A TIG 160A MMA Input...

Page 15: ...e plate of the machine which allowed to be connected and verify the input power supply is consistent with the allowable power supply of the machine f The thread pressing screws must be pressed tightly...

Page 16: ...earth clamp to the quick socket of the output current pole under the front panel and turn clockwise to tighten then clamp the work piece with earth clamp 1 4 Connect the power cord to the distribution...

Page 17: ...der the front panel and tighten it Connect the aviation plug of TIG welding torch to the corresponding interface on the cutting machine panel and screw the interface screw 2 3 Connect the power cord t...

Page 18: ...ork piece 3 TIG welding torch 3 MMA welding process 3 1 Connect the quick plug of the ground cable one end of which is connected with an earth clamp to the quick socket of the output current pole unde...

Page 19: ...parameters on the panel according to the requirements start welding operations when the electrode contacts the work piece 3 6 Carry out the welding operation according to the normal procedure During w...

Page 20: ...sulation layer is not damaged the wiring is correct and the joint piece is not loose COMMON MACHINE MALFUNCTIONS AND SOLUTIONS Warning Machine maintenance must be carried out by qualified professional...

Page 21: ...tage Filter capacitor and bridge rectifier have been damaged resulting in failure to start the machine Replace filter capacitor and bridge rectifier Power frequency transformer damaged Replace power f...

Page 22: ...fan work Error indicator light is off There s high frequency discharge sound and no load output No gas discharge No gas discharge from the input air hose Check and make sure the input air hose works...