1. First check that there is no dirt in the conduits and that there are no structural problems
2. Check that the water inlet and outlet coupling fittings are adequately fastened to the
heat pump
3. Start the filter pump to start the water flow to the heat pump. Set the by-pass again.
4. Reconnect the electrical power supply to the heat pump and turn it ON.
5.4 Check-up
Our heat pumps have been built and developed to last if they have been installed correctly and
can operate in normal conditions. Regular check-ups are important if you want your heat pump
to function efficiently for many years. Below are some recommendations to ensure optimal
working conditions for your heat pump.
1. Make sure that the service panel is easily accessible.
2. Keep the area surrounding the heat pump free of organic waste.
3. Prune any vegetation around the heat pump so that there is sufficient free space
around the pump.
4. Remove any water sprinklers that are near the heat pump as they could cause damage
to it.
5. Prevent rain from running directly onto the heat pump from a roof. Install proper
drainage.
6. Do not use the heat pump if it has been flooded. Immediately contact a qualified
technician to inspect the heat pump and repair it should it be necessary to do so.
Condensation can occur when the heat pump is running. This condensation water can flow
away through an opening in the base pan of the unit. The amount of condensation water will
increase when atmospheric humidity is high. Remove any dirt that could impede the discharge
of the condensation. 10 to 20 litres of condensation water can be produced while the unit is
running. If more condensation is produced, stop the heat pump and wait for one hour before
checking for leaks in the conduits.
Note: a quick way to verify that the water running through the condensation is indeed
condensation is to shut off the unit and keep the pool pump running. If the water stops
running out of the condensation drain, it is condensation. AN EVEN QUICKER WAY is
to TEST THE DRAIN WATER FOR CHLORINE. If no chlorine is detected, the drain water
is a result of condensation.
Also make sure that the air inlet and exhaust passages are free, and prevent exhaust air from
immediately re-entering the unit through the inlet.