Basic VoIP Settings

3.1.1

Choice of Mode and Sign-in

It is important choose the mode the System will utilise, either P2P (peer to peer) or via a SIP server.  The 
selection is done using the ‘DIP Relay 2’ (

picture 7

).  A mode change is not possible by the WEB interface and 

any relay change will only show after a System restart.  All other relay should be in set in the “on” position. 
When switching the System on you will need to wait for about 1 minute for the System to react.

To  restore  to  the  factory  settings,  switch  the  ‘DIP  Relay  3’  to  the  “off”  position  and  restart  the 

System.  After restarting the System return relay 3 to the “on” position.

To set the starting IP address 192.168.1.250 switch ‘DIP Relay 4’ to the “off” position and restart the 

System.  After restarting the System return relay 4 to the “on” position.

There  are  two  options  to  restart  the  System  –  either  by  disconnecting  the  power  supply  or  by 

clicking on “restart” in the WEB interface (in folder service).

The  factory  setting  IP  address  is  192.168.1.250.  If  your  network  address  numbering  system  is 

different (i.e. it does not start 192.168.1.xxx), then it will be necessary to set your address in the 

protocol  properties  TCP/IP  in  your  PC  either  provisionally  or  as  alternative  configuration  (e.g. 

192.168.1.245).   You can then set the System parameters including the new IP address.   After the 

VoIP module restart you can then connect to WEB page of the new IP address.

DIP relays 3 and 4 must be in the “on” position otherwise the new IP address will be change back to 

the factory set IP address on restart.

Write  into  your  WEB  browser  IP  address  of  the  Door  Entry  System.  The  default  address  is 

192.168.1.250 as seen on 

picture 8

 below.

16

 | 

P a g e

Summary of Contents for PT-Door01

Page 1: ...ProTalk Door Entry System PT Door01 PT Door01C PT Door02 PT Door02C PT Door01CAV 1 P a g e...

Page 2: ...d aluminium The unit is powered by either an AC DC 12V power supply which can also power an electric door lock or via a Power over Ethernet PoE system The basic ProTalk Door Entry system includes an o...

Page 3: ...in the building 15 2 3 1 Outbound call 15 2 3 2 Incoming call 15 3 PARAMETER PROGRAMMING 16 3 1 Basic VoIP settings 16 3 1 1 Choice of mode and sign in 16 3 1 2 Language setting 17 3 1 3 Network setti...

Page 4: ...4 TECHNICAL PARAMETERS 32 4 1 Electrical parameters 32 4 2 Mechanical parameters 32 4 3 Video parameters 32 4 P a g e...

Page 5: ...to connect to the door phone 12v power supplies with battery backup option Exit Relays or Bundles of above as complete door entry kits 1 2 Terminology Ethernet is a family of frame based computer net...

Page 6: ...mages Voice over Internet Protocol VoIP is a general term for a family of transmission technologies for delivery of voice communications over IP networks such as the Internet The Internet Protocol Sui...

Page 7: ...consist of a motherboard an IP module a PoE module and a camera see picture 1 for the setting and positioning of the modules We recommend that the system is powered by PoE technology Alternating Curre...

Page 8: ...ystem to accommodate this please see picture 4 Picture 1 Motherboard The connection of relay contact terminals is illustrated on picture 2 The NO annotation means an idle disconnected contact COM mean...

Page 9: ...Picture 2 Connection of the Door Entry System 9 P a g e...

Page 10: ...mechanism max 350mA Voice Communication Setting Volume settings have been preset by the manufacturer The preset position is shown on picture 5 If changes are required these can easily be made by using...

Page 11: ...l and automatically switches off at the end DIP relay setting of base parameters and mode with DIP relay Reserve 1 Change of mode P2P SIP server 2 Basic setting deletes all parameters and changes them...

Page 12: ...1 5 2 Name Tag Back Lighting Disassembly 1 5 3 Wall Mounting The unit can be Wall mounted with the enclosed screws and wall plugs screw driver diameter 5mm 12 P a g e...

Page 13: ...gs after wall mounting 1 5 5 Name Tag Change Each button has a card tag held in place with a plastic cover see picture above Paper name tags of the correct size can be produced in an Excel worksheet i...

Page 14: ...e number dialled by the system will depend on the mode set on the system Mode Day Night if the system is in DAY mode it will always dials the number set in the first column and in NIGHT mode it will a...

Page 15: ...e modes m 1 to m 5 Day Night mode hang up etc 10 seconds into any conversation the system will issue an end of call alert by choosing it is possible to prolong the call the call will then be ended by...

Page 16: ...the System After restarting the System return relay 4 to the on position There are two options to restart the System either by disconnecting the power supply or by clicking on restart in the WEB inter...

Page 17: ...The factory set user name is always admin and the password is 1234 these can be changed in the settings Picture 9 Log in to set up 3 1 2 Language Setting The language is set in the bottom part of menu...

Page 18: ...ignment 3 IP address setting mask setting or any other network setting If you are unsure please contact your network administrator 4 Display of System in current mode Day Night 5 Return to main page w...

Page 19: ...m restart screen will come up see page 26 Important If you are using a DHCP setting the address will be assigned automatically and your network administrator will be able to identify the actual IP add...

Page 20: ...to session progress added for some SIP proxy servers that require this 2 Symmetric RTP added for some SIP proxy servers that require this and 3 Default values will perform basic factory reset After m...

Page 21: ...re registration 4 Choice of signal of incoming call Ringing can be changed to Session progress added for some SIP proxy servers that require this 5 Symmetric RTP added for some SIP proxy servers that...

Page 22: ...he streaming video can be viewed on a telephone Grandstream series GXW3000 which is equipped with a large LCD display Another interesting way to view the video is via the installed Pop Up program UDVg...

Page 23: ...e shown in the header of Pop Up program Video parameters are explained on page 32 3 1 8 Day Intervals Only displays if the automatic Day Night relay is ticked on the basic parameters page Available on...

Page 24: ...switch it back on for security purposes 2 Video on off relay when in VoIP call some systems cannot work with both at once 3 Opportunity to change usual TCP port 80 4 Opportunity to switch on off acces...

Page 25: ...nhanced log and vice versa 2 Click on Download log file and you can save a file to your chosen position This file will have the ending bin which must be changed to tar To open an archived tar file use...

Page 26: ...ts logos etc 8 Upload language uploads or rewrites language support files It is not possible to edit the two basic languages Czech and English 9 Save configuration all files 10 Restore configuration r...

Page 27: ...ting the name use the program PSPad Only translate the terms in quotation marks and ensure that notations are kept in the HTML format 3 2 Door Entry System parameter setting 3 2 1 Basic Parameters 1 D...

Page 28: ...changes the functions of the System 3 2 2 All about Relays 1 Relay modes 1 Switch mode switches on by either command or password for a given time set in relay closing used for electric locks gate ope...

Page 29: ...When choosing the password it is necessary to adhere to the following rules Choose a password in such a way that it is not possible to deduct the combination from worn buttons The first character of...

Page 30: ...ger than the set time the code will not be evaluated correctly Dialling if the button pressed is the same as first character the password for switch on the option will be delayed for this length of ti...

Page 31: ...ephone numbers in column 2 Night Mode can be as long as 16 digits If P2P mode is in use then the IP address will need to be saved in the following format 192 168 1 231 where means If the SIP server mo...

Page 32: ...starts running properly These browsers are preferable to Internet Explorer because the video viewing is smoother and has less impact on the network load Streaming video for IP phones H 263 formatting...

Page 33: ...nt 1 4 pictures second is set in Video setting on the WEB The picture count of both MJPG and Stream H 263 is set by the camera type used however this is normally between 7 12 pictures second Ports Por...

Page 34: ...arranty claims are handled through your dealer Warranty claims should be accompanied by The product in question a description of the problem proof of purchase and your full name and address The warran...