3
PARAMETER
PROGRAMMING
3.1
Basic VoIP Settings
3.1.1
Choice of Mode and Sign-in
It is important choose the mode the System will utilise, either P2P (peer to peer) or via a SIP server. The
selection is done using the ‘DIP Relay 2’ (
picture 7
). A mode change is not possible by the WEB interface and
any relay change will only show after a System restart. All other relay should be in set in the “on” position.
When switching the System on you will need to wait for about 1 minute for the System to react.
To restore to the factory settings, switch the ‘DIP Relay 3’ to the “off” position and restart the
System. After restarting the System return relay 3 to the “on” position.
To set the starting IP address 192.168.1.250 switch ‘DIP Relay 4’ to the “off” position and restart the
System. After restarting the System return relay 4 to the “on” position.
There are two options to restart the System – either by disconnecting the power supply or by
clicking on “restart” in the WEB interface (in folder service).
The factory setting IP address is 192.168.1.250. If your network address numbering system is
different (i.e. it does not start 192.168.1.xxx), then it will be necessary to set your address in the
protocol properties TCP/IP in your PC either provisionally or as alternative configuration (e.g.
192.168.1.245). You can then set the System parameters including the new IP address. After the
VoIP module restart you can then connect to WEB page of the new IP address.
DIP relays 3 and 4 must be in the “on” position otherwise the new IP address will be change back to
the factory set IP address on restart.
Write into your WEB browser IP address of the Door Entry System. The default address is
192.168.1.250 as seen on
picture 8
below.
16
|