PROGRAMMING EXAMPLES
PAGE 41
In this example, the B1290 is used to announce alarms from an unattended location over a building’s public address
system. You want the alarms to be announced twice, repeated again one minute later then repeated for the last time
one minute after this. To make the process stop after the third repetition, program Timer B to zero. A zero value in
Timer B means that the alarm is automatically acknowledged after A Times.
Connect the radio port, TX Audio and PTT, from the B1290 to the PA inputs.
Starting with the timer setup:
B1290:
Enter Program Code
YOU:
B1290:
Answer Rings is 4 (No effect on operation)
YOU:
Next
B1290:
Timer A is 2 minutes
YOU:
Change the timer to 1 minute
B1290:
Timer A is 1 minutes
YOU:
Next
B1290:
Timer B is 10 minutes
YOU:
Change the timer to zero
B1290:
Timer B is 0 minutes
YOU:
Next
B1290:
Times A is 3
YOU:
Change the times A to 2
B1290:
Times A is 2
YOU:
Next
The timers are now set, now put the commands into the directory.
B1290:
Enter Program Code
YOU:
Directory Code
B1290:
Enter Directory
YOU:
Directory A
B1290:
Directory A, Line One is...
YOU:
Change
B1290:
‘beep’
YOU:
[RADIO][ALERT][VOICE][VOICE]
B1290:
Directory A, Line One is RADIO ALERT VOICE VOICE
YOU:
Next
B1290:
Directory A, Line Two is..
YOU:
Quit
B1290:
Enter Directory
YOU:
Quit
Now remove the acknowledge request prompt.
Summary of Contents for Plus B1290
Page 1: ...Installation Operation Manual January 2022 Rev 2 04 ...
Page 4: ......
Page 19: ...OPERATION PAGE 15 ...
Page 49: ...PROGRAMMING EXAMPLES PAGE 45 etc ...
Page 60: ...PAGE 56 APPENDIX C PROGRAMMMING TREE Next ...
Page 61: ...APPENDIX D MOUNTING PAGE 57 15 APPENDIX D MOUNTING Figure 9 Mounting Detail ...